Troubleshooting
In the event of any abnormality, stop the system and utilities supply
(steam, water, air and electricity). Investigate the cause of the
abnormality and take countermeasures. Prevent the supply of utilities to
the system until the countermeasures have been implemented.
WARNING
Use hoisting equipment for heavy objects (weighing approximately
20 kg (44 lb) or more). Failure to do so may result in back strain or other
injury if the object should fall.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
When disassembling or removing the system, wait until the internal
pressure equals atmospheric pressure and the surface of the product
has cooled to room temperature. Disassembling or removing the system
when it is hot or under pressure may lead to discharge of fluids, causing
burns, other injuries or damage.
CAUTION
Be sure to use only the recommended components when repairing the
system, and NEVER attempt to modify the product in any way. Failure to
observe these precautions may result in damage to the system or burns
or other injury due to malfunction or the discharge of fluids.
CAUTION
Make sure the power supply is OFF before carrying out work on the
wiring or inspections involving disassembly. If such work is carried out
with the power on, there is a danger that components may malfunction
or electric shock may occur, leading to injury or other accidents.
CAUTION
Make sure that installation work requiring a special license is carried out
by qualified personnel. Improper work may cause falls, dropped items,
overheating and electrical leaks, leading to injury, burns, fires, damage
and other accidents.
CAUTION
When using this system, NEVER stand close to, or leave tools anywhere
near moving parts, such as the shaft. Contact with moving parts or
objects becoming caught in moving parts could lead to injury, damage
or other accidents.
CAUTION
Do NOT touch terminals when power is on. This may lead to system
breakages, erroneous operation, electrical shock or fires.
CAUTION
When the system fails to operate properly, use the following table to locate the cause
and remedy.
Item
Cause
Diagnostic
Remedy
The pump
does not start
A current is not
applied to the
pump
The power is not turned on
Turn on the power
The wiring is disconnected or not
connected
Connect the wiring
The power is cut off
Apply current to the
pump
The non-fuse
breaker is
operating
There is a short in the sequence
Fix the control system
then reset the non-
fuse breaker
The pump
cannot be
activated
A thermal relay has tripped or the
wiring is disconnected
Disassemble and
clean the pump
If the motor is broken,
replace the motor
Reset the thermal
relay
Continued on the next page