172-65132MA-07 (JX Series) 16 Feb 2022
13
Disassembly/Reassembly
NEVER apply direct heat to the float.
The float may explode due to increased internal pressure, causing accidents leading
to serious injury or damage to property and equipment.
Use hoisting equipment for heavy objects (weighing approximately 20 kg (44
lb) or more).
Failure to do so may result in back strain or other injury if the object should fall.
When disassembling or removing the product, wait until the internal pressure
equals atmospheric pressure and the surface of the product has cooled to
room temperature.
Disassembling or removing the product when it is hot or under pressure may lead
to discharge of fluids, causing burns, other injuries or damage.
Use the following procedures to remove components. Use the same procedures in
reverse to reassemble. (Installation, inspection, maintenance, repairs, disassembly,
adjustment and valve opening/closing should be carried out only by trained
maintenance personnel.)
Disassembling/Reassembling Optional* Lock Release Valve
Part
J(F)3X
J(F)5X
J7.2X
J7X
J7.5X
J8X
During Disassembly
During Reassembly
Gland Case
30
–
–
Remove with a socket
wrench
Consult the table of tightening
torques and tighten to the proper
torque
Gasket 32
–
–
Remove the gasket and
clean sealing surfaces
Replace with a new gasket if
warped or damaged
Gland
Retainer
Nut 29 *
–
–
Remove with a socket
wrench
Consult the table of tightening
torques and tighten to the proper
torque
Gland
Packing 31
–
–
Remove, being careful
not to scratch the inside
of the gland case
Replace with a new gland packing
Spring Pin
34
–
–
Squeeze and remove
Insert until equal lengths of the pin
are visible on both sides of the
element retainer
Element
Retainer 33
–
–
Remove while turning
* Stamped 3 or 5: 3 for J3X and JF3X, 5 for J5X and JF5X