3.3.2 Flow Conditioner (Rectifier)
Control Valve and Flow Conditioner:
Concentric Reducer and Flow
Conditioner:
Concentric Diffuser and Flow
Conditioner:
Eccentric Reducer and Flow
Conditioner:
One 90° Elbow or T-piece and Flow
Conditioner:
Two 90° Elbows (2-Dimensional) and
Flow Conditioner:
Two 90° Elbows (3-Dimensional) and
Flow Conditioner:
Combination Pipe (Elbows & Eccentric
Reducer etc.) and Flow Conditioner:
With limited space and large pipes,
it is not always possible to use the
upstream sections shown in Fig. 4-
1. In such cases the specially
developed perforated plate flow
conditioner (see 6.6) can be fitted
as shown on the right (see Fig. 4-
2). The flow conditioner is held
between two piping flanges and
centered with the flange bolts. It
reduces the length of the upstream
section downstream from flow
disturbances to 8D while
maintaining full measurement
accuracy. The total length of
straight piping downstream
becomes 10D to 13D. Note that a
flow conditioner cannot be used in
conjunction with the Steam
Dryness Fraction Calculator option.
A = Upstream
B = Downstream
D = Nominal Diameter
Flow Conditioner
5D
8D
5D
A
B
Flow Conditioner
2D
8D
5D
A
B
Flow Conditioner
2D+5h
8D
5D
A
B
h
Flow Conditioner
5D
8D
5D
A
B
2D
8D
5D
A
B
Flow Conditioner
5D
8D
5D
A
B
Flow Conditioner
5D
8D
5D
A
B
Flow Conditioner
5D
8D
5D
A
B
Flow Conditioner
Figure 4-2
Upstream and
downstream piping