background image

                                           

    XSNet 3100MC 

5

 

 
 
 
 

 Toggle down Pin 5 to force the FX port at full duplex mode. Or toggle up Pin 5 for half duplex mode. 

 

 Toggle up Pin 1 to disable the link-fault-pass-through. 

 

 Connect the converter to the power again. The new setting will come into effect then.  

 

LED Indicators                                                         

The LED indicators give you instant feedback on status of the converter:  

 

LEDs State 

Indication 

Steady Power 

on 

 
 
 

PWR stands for POWER 

PWR 

Off Power 

off 

Steady 

Connection at the speed of 100Mbps 

100 (Mbps) 

Off 

Connection at the speed of 10Mbps 

Steady 

A valid network connection established 
LNK stands for LINK 

Flashing 

Transmitting or receiving data 
ACT stands for ACTIVITY 

LNK/ACT 

Off 

Neither valid network connection established 
nor transmitting/receiving data 

Steady 

Connection in full-duplex mode 
FDX stands for FULL-DUPLEX 

Flashing Collision 

occurred 

COL stands for COLLISION 

FDX/COL 

Off 

Connection in half-duplex mode 

 

Link-Fault-Pass-Through                                             

Connect the FX ports of two Media Converters A and B through the fiber 
cable. 
 
Link Fault of the FX port:  
A Link Fault condition will be sensed on the TX port whenever the media 
converter detects a Link Fault condition on the FX port. Thus, the 100, 
LNK/ACT, and FDX/COL LEDs of the media converter would be off. 
 
Link Fault of the TX port of the Media Converter A: 
The Media Converter A: A Link Fault condition will be sensed on the FX 
port whenever the media converter detects a Link Fault condition on the 
TX port. Thus, the 100, LNK/ACT, and FDX/COL LEDs of the TX port of 
the Media Converter A would be off. 
 
The Media Converter B: A Link Fault condition will be informed to the FX 
port of the Media Converter B. Then a Link Fault condition will be sensed 
on the TX port of the Media Converter B whenever the Media Converter B 

Содержание Siqura XSNet 3100MC

Страница 1: ...10Base T and IEEE802 3u 100Base TX FX standards In this manual you will find Product overview Features on the media converter Illustrative LED functions Installation instructions Specifications Import...

Страница 2: ...CONTENTS 2 INTRODUCTION 3 PRODUCT OVERVIEW 3 PRODUCT FEATURES 3 PACKING LIST 3 ONE CHANNEL MEDIA CONVERTER 4 PORTS 4 PORT SETTINGS 4 LINK FAULT PASS THROUGH 5 INSTALLATION 7 SELECTING A SITE FOR THE...

Страница 3: ...r transmits with 1550nm wavelength and receives with 1310nm wavelength Auto negotiation of speed and duplex mode on TX port Auto MDIX on TX port One DIP switch for configuring link fault pass through...

Страница 4: ...elow for more details DIP switch No Down Up 1 Enable LFPT Disable LFPT LFPT link fault pass through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX...

Страница 5: ...e FDX stands for FULL DUPLEX Flashing Collision occurred COL stands for COLLISION FDX COL Off Connection in half duplex mode Link Fault Pass Through Connect the FX ports of two Media Converters A and...

Страница 6: ...f the FX port TX Port FX Port LEDs PWR 100 LNK ACT FDX COL LNK ACT FDX COL Media Converter A ON OFF OFF OFF OFF OFF Media Converter B ON OFF OFF OFF OFF OFF Link Fault of the TX port of the Media Conv...

Страница 7: ...hrenheit 0 to 45 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 80...

Страница 8: ...uplex Switching Method Store and Forward Forwarding rate 14 880 148 810pps for 10 100Mbps Per Unit 2 LEDs Power 100 Mbps LED Indicators Per Port 2 LEDs LNK ACT FDX COL Dimensions 80 3mm W 109 2mm D 23...