51
4.
Under communication deselect “Active”.
5.
Copy the password of the line.
6.
Save this record.
Configuration in Pluto:
1.
Browse to the maintenance page of the Pluto.
2.
Login with username “controller” and the line password,
generated in iProtect.
3.
Select the menu “Advanced”.
4.
Press on “Reboot”. Login into the mainten
ance page of the Pluto after 2 minutes.
5.
Select the menu “Advanced”.
6.
Press on “
Make factory default
”.
The Pluto will automatically reboot after 5 minutes.
Note:
The password, configurations and iProtect data will be removed. The IP-address
will not be changed.
7.
Login into the
maintenance page of the Pluto. Login with username “controller” and the
password “Pluto”.
11.9
Pluto
–
Removing iProtect data
When it is necessary to remove the iProtect data, complete the following steps:
Configuration in iProtect™:
1.
Open menu: “Installation” > “Hardware” > “Line”.
2.
Click on the “Search” button.
3.
Select the correct Pluto.
4.
Under communication deselect “Active”.
5.
Copy the password of the line.
6.
Save this record.
Configuration in Pluto:
1.
Browse to the maintenance page of the Pluto.
2.
Login with username
“controller” and the line password,
generated in iProtect.
3.
Select the menu “Advanced”.
4.
Press on “Reboot”. Login into the mainten
ance page of the Pluto after 2 minutes.
5.
Select the menu “Advanced”.
6.
Press on “
Make clean
”.
The following message appears: "enabling apache"
Note:
The password ad ip-address will not be changed. Configurations and iProtect data
will be removed.
7.
The Pluto can be linked with iProtect again. See chapter 11.1.
Содержание KEYPROCESSOR Orion
Страница 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Страница 4: ...4 ...
Страница 57: ...57 14 Technical drawings 14 1 72000310 Pluto Orion setup with network connection and power supply ...
Страница 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Страница 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Страница 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Страница 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Страница 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Страница 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Страница 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Страница 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Страница 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...
Страница 67: ...67 14 11 72000504 Polyx with kpBus ...