21
6.6
SD-card functionality
Additional functionality is available when using an SD card in the Orion. When there is no
communication (kpBus) with the network controller, the local operation of the access will be
guaranteed.
This functionality is available from:
•
iProtect version 8.04 or higher
•
Orion application version 1.4.37 or higher
•
Orion bootloader version 2.3.0.14 or higher
6.6.1
Inserting the SD card
1.
Remove the power from the Orion before inserting the SD card.
2.
The copper slots of the SD card must be facing inwards for inserting the SD card. The
card must be clicked without any pressure. See Figure 12.
Note!
Inserting the SD card incorrectly could cause serious damage to the Orion
or SD card.
6.6.2
Calamity cards
Calamity cards are cards that need access to a door(s) when there is no communication with the
Network Controller (offline).
In an offline situation, the Orion will function fully independently. If a user has a calamity priority,
which is created within iProtect in the card dialog, there will be no noticeable issues for the user.
If the Orion communicates with the Network Controller, all events will be sent to iProtect.
6.6.3
Support in offline situation
The following features are supported during the Offline situation:
The following table shows the maximum numbers:
Storage SD-card
Nr.
Description:
Maximum per Orion:
1
Cards with valid access rights
4.000
2
Events
560.000
The following table shows all the events:
Figure 12: Inserting the SD card
Part number: 501-1905
Содержание KEYPROCESSOR Orion
Страница 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Страница 4: ...4 ...
Страница 57: ...57 14 Technical drawings 14 1 72000310 Pluto Orion setup with network connection and power supply ...
Страница 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Страница 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Страница 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Страница 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Страница 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Страница 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Страница 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Страница 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Страница 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...
Страница 67: ...67 14 11 72000504 Polyx with kpBus ...