background image

TITANOX

 

s.r.l.

 

F

F

A

A

B

B

B

B

R

R

I

I

C

C

A

A

 

 

A

A

R

R

T

T

I

I

C

C

O

O

L

L

I

I

 

 

M

M

E

E

D

D

I

I

C

C

O

O

 

 

S

S

A

A

N

N

I

I

T

T

A

A

R

R

I

I

 

 

M

M

E

E

D

D

I

I

C

C

A

A

L

L

 

 

S

S

A

A

N

N

I

I

T

T

A

A

R

R

Y

Y

 

 

I

I

T

T

E

E

M

M

 

 

F

F

A

A

C

C

T

T

O

O

R

R

Y

Y

 

 

 

 

2

2

6

6

0

0

3

3

8

8

 

 

T

T

o

o

r

r

r

r

e

e

 

 

d

d

è

è

 

 

P

P

i

i

c

c

e

e

n

n

a

a

r

r

d

d

i

i

 

 

(

(

C

C

R

R

)

)

 

 

 

 

I

I

T

T

A

A

L

L

Y

Y

 

 

 

 

V

V

i

i

a

a

 

 

C

C

a

a

n

n

o

o

v

v

e

e

,

,

 

 

2

2

/

/

A

A

 

 

 

 

C

C

a

a

n

n

o

o

v

v

e

e

 

 

d

d

è

è

 

 

B

B

i

i

a

a

z

z

z

z

i

i

 

 

T

T

e

e

l

l

.

.

 

 

(

(

0

0

0

0

3

3

9

9

)

)

 

 

0

0

3

3

7

7

5

5

 

 

3

3

9

9

4

4

0

0

6

6

5

5

 

 

(

(

r

r

.

.

a

a

.

.

)

)

 

 

 

 

F

F

a

a

x

x

 

 

(

(

0

0

0

0

3

3

9

9

)

)

 

 

0

0

3

3

7

7

5

5

 

 

3

3

9

9

4

4

0

0

6

6

7

7

 

 

H

H

o

o

m

m

e

e

 

 

p

p

a

a

g

g

e

e

:

:

 

 

h

h

t

t

t

t

p

p

:

:

/

/

/

/

w

w

w

w

w

w

.

.

t

t

i

i

t

t

a

a

n

n

o

o

x

x

.

.

c

c

o

o

m

m

 

 

 

 

E

E

-

-

M

M

a

a

i

i

l

l

 

 

i

i

n

n

f

f

o

o

@

@

t

t

i

i

t

t

a

a

n

n

o

o

x

x

.

.

c

c

o

o

m

m

 

 

USEFUL LIFE 

 

 

The useful life of the device is established in years 5 from the commissioning. For this period Titanox s.r.l. 
guarantees the availability of spare parts and safe operation as long as the environmental and use conditions 
defined in the instructions for use are respected by the user. 
The supplier of the electronic card states that "the capacity of the memory of the mounted microprocessor is 
1,000,000 cycles. By cycle we mean every ignition of the card: therefore in 10 years (3650 days) 274 daily 
ignitions are allowed ... " 
The manufacturer of the microprocessor does not guarantee its availability in the next 10 years: for this reason 
TITANOX has decided to reduce the "useful life" to 5 years, thus having the tranquillity of being able to provide 
customers with an efficient after-sales service. 

 

 
 
 
 

 

INSTRUCTIONS MANUAL 

 

DRY HEAT STERILIZING UNIT  

MOD. PASTEUR ELECTRONIC 

 
 
 
 
 
 
 

 

 
 
 

 
 

 
 
 

 

 
 
 
 
 
 
 
 

 
 

 
 
 

 

 

 

 

 

Rev. 16   2019-02-26 

THESE INSTRUCTIONS HAVE ALWAYS TO FOLLOW THE UNIT. 
FOR SAFETY WARNINGS PLEASE READ THE INSTRUCTIONS ON PAG. 6 

0476

 

Содержание A3-216-400

Страница 1: ...ning For this period Titanox s r l guarantees the availability of spare parts and safe operation as long as the environmental and use conditions defined in the instructions for use are respected by the user The supplier of the electronic card states that the capacity of the memory of the mounted microprocessor is 1 000 000 cycles By cycle we mean every ignition of the card therefore in 10 years 36...

Страница 2: ...working of the device 6 The warranty expires when the device is tampered with or repaired by unauthorised personnel 7 It is excluded the substitution and the extension of the warranty following a breakdown 8 It is excluded any compensation for damages direct or indirect of any nature to persons or objects arising from use or suspension of use of the device 9 The warranty expires immediately if the...

Страница 3: ...rials whose melting point is higher than 300 C surgical instruments plates and metal screw Inside the sterilizer place only metal containers without plastic parts and without textile material FORBIDDEN USES It is forbidden to place in the device items whose melting temperature is lower than 300 C or is not known to the operator ACCESSORY PARTS 2 Internal shelves 1 Mains cable SELLING OFF The steri...

Страница 4: ...on display TEMP C Pos 9 shall appear the ward ECH Electronic Compensation High 11 At the end of the internal compensation working on display TEMP C Pos 9 shall appear the current internal temperature that persist with no time limit 12 To terminate the sterilization procedure in continuous cycle running press the button SELECT Pos 12 PLEASE NOTE If change of heating procedure is required re check e...

Страница 5: ...e activation of the resistances for maintaining the temperature programmed In case of abnormality of the driving system of the resistances on display TIME Pos 10 the indication FAL is shown and the green LED Pos 13 shall remain off TECHNICAL SPECIFICATION The device is in conformity to electrical safety norms provided for by the normative institutes and supplied with bipolar plug which assures per...

Страница 6: ... system has electrical grounding and that it s in conformity to the safety norms in the country of installation Do not remove any label or plate in case of need ask for more Always insist on original spare parts Do not open the door of the device until the thermometer of the internal temperature do not indicate a temperature lower than 30 C Medical devices before being placed in the sterilizer sho...