OPERATION OF THE GENERATOR
Connecting electrical loads
Let engine stabilize and warm up for at least 3
minutes.
Make sure devices to be connected are in good
working order and in the “OFF” position before
connecting to the generator.
Make sure to plug in desired devices into the
correct receptacle.
DO NOT connect 240 Volt loads to the 120 Volt
duplex receptacles.
DO NOT connect 3 phase loads to the genera-
tor.
DO NOT connect 50 Hz loads to the generator.
This is a 60Hz System.
DO NOT overload the generator. Add up the
rated Watts of all loads to be connected. This
total should not exceed the total watts of the
generator.
Stopping the engine
Turn off all electrical devices connected to the
generator.
WARNING:
DO NOT start or stop generator with electrical
devices plugged in.
Allow the generator engine to run at a ‘No Load’
condition for several minutes to stabilize internal
engine temperature before stopping
Turn the On\Off switch to the “OFF” position. on
the control panel.
Turn fuel valve to the “OFF” position
Generator maintenance
(see maintenance table for list page 8).
Keep the generator clean and dry. Use a damp
cloth to clean exterior surfaces. Remove caked
on dirt with a soft brush.
Never spray with water. Water can contaminate
the engine fuel system and cause serious prob-
lems in the generator.
Damage may occur if engine or carburetor clean-
ing products are used.
Storage
IMPORTANT:
(See Page 11)
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Starting the engine
z
5
1. Check oil and fuel levels
2. Turn fuel valve to the “ON” position
3. Put choke lever in the “ON” position
4. Turn the On\Off switch on the control
panel to the On Position
5. Pull the Recoil Starter Briskly until
engine is running.
5. Return choke lever to the “OFF” posi-
tion