16
No.
Component illustration
LP control box display panel
NG control box display panel
Reset operation
: When the
system fails, it will lock-out
automatically, and you need to
press and hold the Reset button
to manually reset it.
(
Note:
Power cut-off and restart
will not release the fault. You
must press and hold the Reset
button to reset the system
manually).
Automatic Electrical Burner Control System Panel Indicator Light Status Description
Indicator Status
Operating State
1
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
OFF
ON
ON
Normal Running Position
2
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
OFF
OFF/ON
OFF/ON
Trial for Ignition Period
Either the Main valve or Pilot valve can be open during this
period, not both.
3
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
Flashing
OFF
OFF
OFF
Operating Paused
The tip-over switch shut-off or the input voltage is lower than
90 V AC (+ -5 V), the system will resume operation after the
voltage is restored for 10 sec.
4
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
ON
Flashing
OFF
System Lock-Out
Main flame valve fault, Main fire flame sensor fault
5
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
ON
OFF
Flashing
System Lock-Out
Pilot flame valve fault, Pilot fire flame sensor fault
6
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
ON
Flashing
Flashing
System Lock-Out
Main / Pilot flame valve fault
Main / Pilot fire flame sensor fault
7
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
ON
Flashing
OFF
OFF
System Lock-Out
Key failure or monitoring PCB failure. Please restart the
system by reconnecting the power and long pressing the
Reset button. If long pressing the Reset button does not work,
there is a critical failure.
8
MAIN Power On
Lock Out(error)
Main Valve On
Pilot Valve On
Flashing
Flashing
Flashing
Flashing
System Lock-Out
System self-checking (Memory, Flash, system clock error).
Liquid Propane
Reset
(Press for 2 sec.)
Greenhouse
heater
Natural Gas
Reset
(Press for 2 sec.)
Greenhouse
heater