30
Fig.19
–
Installation of card reader into the turnstile pedestrian gate «JETPAN»
2.3 Turnstile preparation for use
2.3.1 Commissioning guidelines
Prior to the turnstile energization:
1) make sure of proper connection and good condition of all connecting cables;
2) clear the turnstile leaf swing area from foreign particles.
When mains cable of power supply unit is connected to the network the turnstile operating
mechanism is energized: leaves are locked from swinging in both directions barring access.
The turnstile is put in initial state: Entry and Exit LED display is blue.
The turnstile performance to be checked at least 10 times in both directions upon generation
of the appropriate opening command (entry, exit).
2.3.2 Required inspections
Содержание JETPAN
Страница 1: ...1 TiSO PRODUCTION LTD WAIST HIGH TURNSTILE JETPAN OPERATION MANUAL AUIA 168 OM rev 1 2018 ...
Страница 44: ...44 Annex C 1 mandatory Wiring diagram of the JETPAN type turnstile ...
Страница 48: ...48 Annex D 4 mandatory Diagram of the turnstile connection to control panel 5 4 3 2 1 P B A G ...