20
Table 6
№
Connector
/contact
Descriptio
n
Direction
Designation
Signal description and
parameters
X1/1
IN1
ENTRY
«TO BE OPENED A»
1)
logical “0”
(0
1,7) V; 2)
2)
logical “1”
(3,7
5) V; 3)
3)
active level of signal
–
logical “0”;
4)
voltage on open input
≤ 5 V
X1/2
IN2
ENTRY
«LOCK»
X1/3
IN3
ENTRY
Not applicable
X1/4
IN4
ENTRY
Not applicable
X1/5
IN5
ENTRY
To be connected to
magnetic sensor
X1/6
IN6
ENTRY
X1/7
IN7
ENTRY
X1/8
IN8
ENTRY
X1/9
GND
“
-
“ power supply
(common wire)
X1/10
GND
X1/11
GND
X1/12
+5 V
EXIT
Not applicable
X2/1
GRN1
EXIT
Not applicable
X2/2
RED1
EXIT
Not applicable
X2/3
GRN2
EXIT
Not applicable
X2/4
RED2
EXIT
Not applicable
X2/5
-
MG1
EXIT
Not applicable
1)
type of output
–
open collector;
2)
peak voltage on
privacy key 50V;
3)
peak current of
public key 5A
X2/6
+MG1
EXIT
Not applicable
X2/7
-
MG2
EXIT
Not applicable
X2/8
+MG2
EXIT
Not applicable
X2/9
MOT1
EXIT
Connection of motor
1)
voltage (10 ÷ 27)V;
2)
current ≤ 4 А
X2/10
MOT2
EXIT
X2/11
GND
“
-
“ power supply
(common wire)
X2/12
+24 V
ENTRY
“+” power supply
(energization of controller)
1) voltage (10 ÷ 27)V;
2) current ≤ 4 А
Х3
Х3
ENTRY
/
EXIT
Communication port
1) logical “0” (0 ÷ 1)V;
2) logical “1” (3,5 ÷ 5) V