20
Continued Table 8
1
2
3
4
5
ХТ1/4
INP4
(«
TO BE OPENED
A»)
ENTRY
"TO BE OPENED FOR
SINGLE/FREE ACCESS"
command. Input is activated
within the time of holding in
active state. Free access is
occurred when entry is kept
in active state after rotor
reaches the angle 120º.
ХТ1/5
INP5
(«
TO BE OPENED
B»)
ENTRY
ХТ1/6
GND (common)
«
-
» power supply
(common wire)
ХТ2/1
GND (common)
ХТ2/2
OUT1
(«START OF
ACCESS А»)
EXIT
Signal is generated by
controller when rotor
revolves from 6º to 54º in
the relevant direction
1) Type of output -
open collector.
2) Peak voltage on
public key 55 V
3) Peak current of
public key 100 mA
4) Resistance of
public key (5 ÷ 7)
Ohm
5) Active level of
signal (Factory
setting) - Logical
«0»
ХТ2/3
OUT2
(«
START OF
ACCESS
В»)
EXIT
ХТ2/4
OUT3
(«DETECTION OF
ACCESS А»)
EXIT
Signal is generated by
controller when rotor
revolves from 64º to 120º in
the relevant direction
ХТ2/5
OUT4
(«DETECTION OF
ACCESS В»)
EXIT
ХТ2/6
OUT5 («
ACCESS IS
OCUPIED
»)
EXIT
Signal is generated by
controller when rotor
revolves from 6º to 120º in
any direction
ХТ2/7
OUT6
(«ERROR »)
EXIT
Signal is generated by
controller when violation of
operation logic is detected
ХТ2/8
OUT7
(«
PANIC
»)
EXIT
Signal is generated by
controller when “PANIC”
function is activated
ХТ3/1
OPTO1
ENTRY
It is used for acquisition of
data about the turnstile
rotor position
1) 1) Logical «0»
(0 ÷ 2,2) V
2) Logical «1»
(3 ÷5) V
3)Active level of
signal (Factory
setting)
-
Logical
«0»
4) Voltage on open
input < 5 V
ХТ3/2
OPTO2
ENTRY
ХТ3/3
OPTO3
ENTRY
ХТ3/4
SGN1
ENTRY
Not applicable
ХТ3/5
SGN2
ENTRY
Selection of turnstile
modification
ХТ3/6
SGN3
ENTRY
Not applicable
ХТ3/7
SGN4
ENTRY
Not applicable