Installation and Operation Manual

Due to the dynamic nature of product design, the information contained in this 
document is subject to change without notice.  Broadcast Tools, Inc., assumes no
responsibility for errors and/or omissions contained in this document.  Revisions 
of this information or new editions may be issued to incorporate such changes.

Broadcast Tools® is a registered trademark of Broadcast Tools, Inc. 

Copyright, 1989 - 2005 by Broadcast Tools, Inc.  All rights reserved.

No part of this document may be reproduced or distributed without permission.

Visit 

www.broadcasttools.com

for important product update information.

Firmware Version 1.06PIC / 01.08XP

Manual update 7/18/2005

SRC-2X 

Ethernet Serial Remote Control 

Содержание SRC-2X

Страница 1: ...Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2005 by Broadcast Tools Inc All...

Страница 2: ...TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information...

Страница 3: ...res to suppress RF Surge protection with RF filtering such as the Tripp Lite ISO BAR 4 or 6 is also suggested for the wall transformer Rack mounting The SRC 2X may be rack mounted using the optional R...

Страница 4: ...U SRC 2X 1 06 or latest PIC firmware version This is also displayed at power up or reset Dipswitch 3 ON Dipswitch 4 OFF Pair mode inputs from one SRC 2X will map directly to the outputs of another SRC...

Страница 5: ...for input 2 enter 212345 0D 0A and hit the ENTER key to terminate Up to 48 characters can be entered for each input NOTE 0D counts as three characters OUTPUT 1 Non volatile string data that will be ou...

Страница 6: ...switch or router NOTE If you are attaching the SRC 2X directly to your computer you MUST use a XOVER CAT 5 cable 3 Connect the supplied 7 5 VDC power supply to the SRC 2X power jack Verify that the po...

Страница 7: ...Verify that the power led and left LINK led above the RJ 45 is lit Quick Start Application Example 1 4 Start the Device Installer software a Click on SEARCH b When the SRC 2X is found click on the li...

Страница 8: ...parameter type the value and press Enter or to confirm a current value just press Enter SRC 2X Channel 1 Basic parameters Hardware Ethernet IP Address 192 168 001 017 Baud rate 9600 I F mode 4C Flow 0...

Страница 9: ...y that the power led and left LINK led above the RJ 45 is lit 4 Start the Device Installer software a Click on SEARCH b When the SRC 2X is found click on the listed device If more that one SRC 2X is f...

Страница 10: ...ress 192 168 001 016 Remote Port No 10001 Connect mode C1 Disconnect Mode 00 Flush Mode 00 When you are finished save the new configurations option 9 The SRC 2X will now reboot Go back to step 1 of Qu...

Страница 11: ...k on the listed device If more that one SRC 2X is found refer to the MAC address label attach to the bottom of the SRC 2X case and click on the desired SRC 2X which should be highlighted c Click on th...

Страница 12: ...te Port 10001 Connect mode CC Datagram Type 01 When you are finished save the new configurations option 9 The SRC 2X will now reboot Go back to step 1 of Quick Start Application Example 3 to set up th...

Страница 13: ...save the new configurations option 9 The SRC 2X will now reboot Go back to step 1 of Quick Start Application Example 3 to set up the next SRC 2X but enter the Channel 1 data listed below SRC 2X numbe...

Страница 14: ...through CAT 5 cable to the RJ 45 connector on the SRC 2X labeled Ethernet and the other end to your hub switch or router NOTE If you are attaching the SRC 2X directly to your computer you MUST use a X...

Страница 15: ...e the value and press Enter or to confirm a current value just press Enter SRC 2X Channel 1 Basic parameters Hardware Ethernet IP Address 192 168 5 10 Note Use the IP address assigned to the COM Port...

Страница 16: ...c Domain The domain name of your email server d Recipient 1 Full e mail address of the first recipient e Recipient 2 Full e mail address of the second recipient 2 Connect the supplied straight through...

Страница 17: ...il settings 5 Expert settings 6 Security 7 Factory defaults 8 Exit without save 9 Save and exit Your choice c Select option 3 and press Enter d To enter a value for a parameter type the value and pres...

Страница 18: ...in euroblock screw terminals Power 2 1mm coax center positive EMI Compliance Class B limits of EN 55022 1998 FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to...

Страница 19: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLI...