MODEL CPV-2 VOLTMETER 

Model CPV-2 

The  Model  CPV-2  Cathodic  Protection  Voltmeter  is  used  for  measuring  D.C.  potentials  on  buried  or 
submerged metal structures. 
 

Unpacking 

Check all components against packing list.  If damage has occurred in shipment, file a claim with the carrier 
immediately.  If it is necessary to contact your supplier or the manufacturer concerning damaged or missing 
items,  be  sure  to  include  all  the  information  such  as  serial  number,  purchase  order  number  and  invoice 
number.  This will ensure you of obtaining proper and expeditious service. 
 

Operating with Half Cell Electrode Attached 

A.  Remove protective vinyl cover from end of half cell electrode. 
B.  Place ceramic end of half cell in contact with moist earth.  (Half cell must be properly prepared.) 
C.  Connect test lead from negative terminal on instrument to the structure. 
D.  Observe and record meter reading.  

Note:

 No switch to push for taking reading. 

 

 

Differences Between Methods Of Connection

  

The Model CPV-4 has a connection for the halfcell to screw into the back of the voltmeter. When using this option, 
the halfcell is connected to the Positive (+) side of the voltmeter. A test lead is then connected between the 
Negative (-) post of the voltmeter and the structure.

  

This setup is used by many companies and technicians, as a "good" read, for instance 0.85v, is displayed as a 
positive number. Many companies and technicians like to use positive numbers in recording reads. Also, an 
analog meter may not display a negative reading, so companies or technicians who have both digital and analog 
meters have standardized using this method.

  

However, there are some groups that teach a different connection method. NACE International and Peabody's 
Control of Pipeline Corrosion, for example, both suggest connecting the Negative (-) terminal to the half cell, and 
the Positive (+) to the structure. This would then change the polarity of the reading, so that the same reading as 
given in the previous example would then be displayed as -0.85v. 

  

To connect the Model CPV-4 CP Voltmeter using the NACE / Peabody method, do not screw the half cell into the 
voltmeter. Use both lead cables provided, connecting the Red (+) cable between the structure and the Positive (+) 
terminal on the voltmeter, and the Black (-) cable between the half cell and the Negative (-) terminal on the 
voltmeter.

  

 

Operation Without Half Cell Electrode 

Use same as any standard voltmeter for measuring D.C. potentials from 0 - 2 volts. 
 

Battery Test 

To check batteries, depress red button on instrument panel.  Instrument should not be in operating position 
while testing batteries.  Maximum battery drain is in the order of 110 microamperes; therefore, they should 
have a life expectancy of nearly one year. 