2.

 

Reset 

1.

 

Simultaneously press   and   for 3 seconds. Continue pressing the buttons until both columns are 

in the lowest position. When finished with the reset, the control box will make a “beep” sound and the 

buttons can be released. 

 

 

 

 

 

 

2.

 

When finished with the reset, the display will show the starting height.   

3.

 

Users must conduct a reset when operating the desk for the first time. 

 

 

Содержание TDH13P

Страница 1: ...Hand Control Programming TDH13P Version 4 August 2021 1 of 10 error codes 20210811 User Manual HandControl Programming TDH13P...

Страница 2: ...terface Guide 4 2 Reset 5 3 Adjusting the Height 6 4 Setting the Memorized Position 6 5 Setting the upper and lower height limit 7 6 Presetting the Desk Starting Height 8 7 Switching Metric and Imperi...

Страница 3: ...sclaimer This user manual is ONLY for generic TiMOTION products Manufacturers may have altered product settings causing them to differ from this user manual Please contact the manufacturer for a revis...

Страница 4: ...Hand Control Programming TDH13P Version 4 August 2021 4 of 10 1 User Interface Guide 3 digit height display Memory setting buttons Up and down buttons...

Страница 5: ...nue pressing the buttons until both columns are in the lowest position When finished with the reset the control box will make a beep sound and the buttons can be released 2 When finished with the rese...

Страница 6: ...4 memory positions How to memorize a position 1 Adjust the desk to the desired height 2 Press preferred memory button 1 2 3 4 with either or for 2 seconds once the display shows P1 or P2 or P3 or P4...

Страница 7: ...being set 2 Repeat instructions 2 4 above to disable the upper limit setting C Setting the lower height limit 1 Adjust the desk to the preferred lower height limit 2 Press and buttons together for le...

Страница 8: ...10 seconds the display will stop flashing and this will confirm that you have successfully set the starting height 7 Switching Metric and Imperial Unit 1 Press memory buttons 1 2 and 4 for 5 seconds...

Страница 9: ...des The digital display shows the error codes below to suggest the issues that users may encounter during the operation Note 4 Error code Descriptions 000 Resetting E00 Not reset completely E01 Overus...

Страница 10: ...no buttons are pressed within 25 seconds Press any button to light up the display again The system goes into 0 1W standby mode Note 5 if no buttons are pressed within 30 seconds Long pressing any butt...

Отзывы: