![Timotion TA16 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/timotion/ta16/ta16_user-manual_1118236011.webp)
User Manual-TA16
Version
D
January 2021
11 of 22
11
Wiring definitions
2.3
Shown below are the standard wiring definitions of the actuator. If your actuator is ordered with customized
wiring, please contact TiMOTION sales for detailed information.
2.3.1
Limitations for limit switches/output signals
In general, the TA16 cable can have a maximum of 6 pins– (2 power wire pins and/or up-to 4 signal wire
pins)
The function limitations for limit switches to output signals are shown in the table below:
Functions for limit switches
Signal output
Without
POT
Single Hall
Double Hall
2 limit switches to cut the current
OK
2.3.2
OK
2.3.8
OK
2.3.6
OK
2.3.7
2 limit switches to cut the current
one additional limit switch for signal output
OK
2.3.3
x
x
x
2 limit switches for signal output
OK
2.3.5
x
x
x
2 limit switches for signal output
one additional limit switch for signal output
OK
2.3.4
x
x
x
* OK = Selectable
** x = Not Compatible
Note:
Please contact the TiMOTION sales engineer if the signal outputs are customized.