Installation & Oper
ating Ins
tructions
Tamper Proof
Room Thermostat
Model: TRT032N
Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Tamper Proof Room Thermostat Model TRT032N ...
Страница 2: ...at the total load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth only Do not use any liquid cleaners 3 Technical Specifications 230V AC 50 Hz This time switch is of Class ll Construction and must not be earthed Switch Rating 6 2 A Switch Type Single pole single throw SPST Connection Type...
Страница 3: ...nt 3CYC Gas 6CYC Oil set by DIP switch Tamper proof cover with retaining screw CE Compliant Dimensions H x W x D 86 x 88mm x 38mm TRT032N Front View Set temperature adjustment scale Tamper proof cover Easy set dial adjuster ...
Страница 4: ...ll using the wall plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into the holes 5 4 Pass the 230V 50Hz mains supply and load cables through the opening of the wall plate Allow sufficient excess cable to wire up the unit but not too much to make it difficult to close t...
Страница 5: ...all plate retaining screws are loosened enough to clear the TRT032N body then engage the top of the TRT032N onto the wall plate retaining tabs and push firmly downwards and then upwards There will be some resistance from the terminals 5 8 Once in place secure with the retaining screws making sure not to over tighten TRT032N Wall Plate Loop terminal ...
Страница 6: ...ins Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N A Loop Terminal is provided should a 3 core cable be used Load Boiler Switch Live Brown or Red to NO 6 Connection Diagram Connect the 230V 50Hz mains supply and load cables to the terminal block which are marked as follows Note Check boiler instructions before connecting ...
Страница 7: ...the set temperature the thermostat will intermittently turn the heating ON and OFF to help prevent temperature over shoot The boiler type can be set to either 3CYC Gas or 6CYC Oil using the DIP switches on the rear of the unit 8 Operation Restore mains to the unit after making sure to check all system wiring is complete and after you have selected the desired DIP switch settings Use the dial adjus...
Страница 8: ...ard Customer Helpline 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A...