Installation & Oper
ating Ins
tructions
Frost Thermostat
Model: TRT031N
Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Frost Thermostat Model TRT031N...
Страница 2: ...t the total load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth only Do not use any liqu...
Страница 3: ...t 3CYC Gas 6CYC Oil set by DIP switch Tamper proof cover with retaining screw CE Compliant Dimensions H x W x D 86 x 88mm x 38mm TRT031N Front View Set temperature adjustment scale Tamper proof cover...
Страница 4: ...l using the wall plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into...
Страница 5: ...ll plate retaining screws are loosened enough to clear the TRT031N body then engage the top of the TRT031N onto the wall plate retaining tabs and push firmly downwards and then upwards There will be s...
Страница 6: ...ns Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N A Loop Terminal is provided should a 3 core cable be used Load Boiler Switch Live Brown or Red to NO 6 Connection Diagram Conn...
Страница 7: ...e over shoot The boiler type can be set to either 3CYC Gas or 6CYC Oil using the DIP switches on the rear of the unit 8 Operation Restore mains to the unit after making sure to check all system wiring...
Страница 8: ...rd Customer Helpline 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your sup...