background image

Ins
tallation & Oper

ating Ins

tructions

DALI  

Power Supply

Model: PSUDALI 

Содержание PSUDALI

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s DALI Power Supply Model PSUDALI...

Страница 2: ...on or maintenance ensure the mains supply to the product is switched off and the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is co...

Страница 3: ...construction and must not be earthed Output voltage 16V DC Output current 220mA Max Rated power 3 8W Max Fixing Hole Centres 105 3mm Operating Temperature 20 C to 45 C IP20 Rated for restricted inter...

Страница 4: ...sition of the fixing holes b Drill the holes for the rawl plugs ensuring not to infringe on any gas water pipes or electrical cables that may be hidden below the surface c Insert the correct rawl plug...

Страница 5: ...am See section 5 Connection Diagram ensuring correct polarity is observed and any bare conductors are sleeved Ensure the terminal screws are secure but do not overtighten 4 5 Close the hinged terminal...

Страница 6: ...replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible r...

Страница 7: ...For a product brochure please contact Qualified Customer Support Coordinators will be online to assist in resolving your query If you experience problems do not immediately return the unit to the sto...