Installation & Oper
ating Ins
tructions
3000W Multi PIR
Light Controller
Model: MLB3000 – Black
Model: MLW3000 – White
Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 3000W Multi PIR Light Controller Model MLB3000 Black Model MLW3000 White...
Страница 2: ...rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 12 metres at a 2...
Страница 3: ...the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc inclu...
Страница 4: ...Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into the holes Diagram D Diagram G Diagra...
Страница 5: ...t is not required simply remove from the unit and discard Place the round end of the tether into the keyhole shape location hole on the wall plate Ensure the tether is securely fixed into the slot bef...
Страница 6: ...tly and the unit is in Test Mode Adjust the sensor head to the desired direction for best coverage See diagram B Test Mode Three LED s Visible The lamp will now illuminate for approximately 2 seconds...
Страница 7: ...The setting is best achieved by the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols 1 Set the DUSK control knob fully anti clockwise 2 When the ambient...
Страница 8: ...d see diagram G This time adjustment is factory set to 1 hour Fully anti clockwise is 1 hour fully clockwise is 8 hours Note If the light is still ON at dawn before the set time expires it will automa...
Страница 9: ...n will operate as a PIR unit until dawn Switch the internal wall switch circuit breaker 3 times off on off on off on within 2 seconds A single flashing red LED at the top of the sensor head indicates...
Страница 10: ...he warm up period should never exceed 5 minutes Occasionally wind may activate the PIR Also passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to all...
Страница 11: ...stage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent The level of ambient light in the area may be too dark for the current DUSK setting During day...
Страница 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...