Clock Synchronisation - Master and Slaves
To synchronise the clocks of multiple Timecode Systems devices, you need to set up
a BLINK network. A BLINK network is a group of devices that are all set to the same
country/area and the same RF Channel.
In the BLINK network, you need to have one 'master' device (a Timecode Systems
device set to run in
Master TX
mode). The master device has the clock settings that
you want all of the devices to use. All of the other devices in the BLINK network
should be set to run as 'slaves'.
When a slave device is on, it transmits a signal (via the set RF Channel). If there is a
master device within range and using the same RF Channel, the master detects the
slave. It then sends its clock settings to the slave. The slave sets its own clock to
match the clock of the master.