24 HOUR
IMMERSION HEATER
TIME CONTROLLER
Cat. No TS900B
3 Year Guarantee
In the unlikely event of the product becoming faulty due to
defective material or manufacture within 3 years of the date
of purchase, please return it to your supplier in the first year
with proof of purchase and it will be replaced free of charge.
For the second and third years or any difficulty in the first
year telephone the helpline on
020 8450 0515
67-058-270
4
OPERA
TING INSTRUCTIONS
This product must not be used on a load
greater than 3kW resistive.
Warning: Continuity of earthing must be maintained. If you have
any doubt about your ability to install this Timeswitch correctly
consult a competent electrician. The IEE Wiring Regulations
require that a means for disconnection from the supply having
a contact separation of at least 3mm in all poles must be
incorporated in the fixed wiring. Your consumer unit normally
complies. All conductors should be 1.5mm2 min.
OPERATING INSTRUCTIONS.
1. Remove the setting pins and insert them at the times you wish
the switch to operate. ON = Inner Circle OFF = Outer Circle.
The shortest period is half-an-hour. Unused setting pins are
stored in the front of the unit.
2. Turn the programme ring clockwise, one complete turn, to
check the programme. Set the programme ring to the correct
time of day at the time indicator.
3. It is possible to manually override the programmed time by
operating the override switch in the right hand corner.
1 = ON. O = OFF.
Notes: a. The override switch cannot be used within 15 minutes
either side of a switching time.
b. Remember to reset the time following power failure.
Specifications
Operating Temp:
0°C to 50°C
Operating Voltage:
230V AC 50Hz
Switch Rating:
13 amp resistive (3kW)
5 amp inductive
400W filament lighting
100W of any type of Low Energy or
Fluorescent
Lighting
Conforms to Directives:
73/23/EEC & 89/336/EEC
Not suitable for discharge lighting (eg SON & Metal Halide).