Time Guard SLW360 Скачать руководство пользователя страница 1

INST

ALLA

TION & OPERA

TING

INSTRUCTIONS

360º SURFACE MOUNT

CEILING PIR LIGHT

CONTROLLER

Cat No. SLW360

SLW360_Instruct_art_2.1.qxd  3/5/06  9:28 am  Page 12

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание SLW360

Страница 1: ...I N S TA L L AT I O N O P E R AT I N G I N S T R U C T I O N S 360 SURFACE MOUNT CEILING PIR LIGHT CONTROLLER Cat No SLW360 Downloaded from Elcodis com electronic components distributor...

Страница 2: ...ully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This...

Страница 3: ...ation 4 core cable may be used there is no external junction box A bridge is provided prewired to bridge across live supply from AC mains to the output load In the above illustration the L1 L2 termina...

Страница 4: ...rescent low energy lighting Do not attempt to install during wet weather if you are suffering from nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified...

Страница 5: ...electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation All fittings should be installed by competent person in accordanc...

Страница 6: ...factory fitted bridge wire Connect the 3 core mains supply cable to the terminal block on the unit as follows NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Connect the load in series with the load s...

Страница 7: ...approximately six metre diameter circle from the centre of the sensor location As you cross a detection zone the lamp will illuminate Now stand still until the lamp extinguishes this should take appr...

Страница 8: ...earlier wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative SLOWLY a small step at a time rotate the control in a clockwise direction until...

Страница 9: ...fit the top cover by aligning the arrows shown on diagram E and twisting clockwise until cover is secure Manual Override Mode The light can be switched on for longer time periods by use of the Manual...

Страница 10: ...that the unit will not detect through glass e g in a glazed porch The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness...

Страница 11: ...ecifications Problem Detection range varies from day to day Solution PIR detectors are influenced by climatic conditions The colder the ambient temperature the more effective the sensor will be You ma...

Страница 12: ...roduct becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier in the first year with proof of purchase and it will be replace...