TIGER
PLUS
CAST-IRON MULTI-FUEL STOVE
INSTALLATION AND OPERATING
INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !
THE INSTALLATION AND SERVICING OF THIS APPLIANCE MUST BE SUPERVISED BY A
QUALIFIED SOLID FUEL ENGINEER. THE SUPPLIERS WILL ACCEPT NO RESPONSIBILITY
WHATEVER FOR APPLIANCES NOT SO INSTALLED.
A register of qualified engineers is available from:
UK: The Solid Fuel Association, 7 Swanwick Court Alfreton Derbyshire DE55 7AS Tel:0845-601-4406 www.solidfuel.co.uk
RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie
This document is a guide to installing and using the Tiger Plus stove, any
national or local regulations must be complied with. Building regulations for
the UK, RoI and IoM can be found at
www.tiger-stoves.com
ASBESTOS:
Tiger does not contain asbestos, but you should be careful to
avoid disturbing any asbestos when removing an old installation.
FIRE CEMENT
is caustic - wash your hands thoroughly after using it.
WEIGHT
Protect your spine by moving the stove only with assistance.
FUME EMISSION:
Properly installed and operated this appliance will not
emit fumes into the dwelling. Occasional fumes from de-ashing and
refuelling may occur. However, persistent fume emission is potentially
dangerous and must not be tolerated. If fume emission persists, then the
following immediate action should be taken:
(a) open doors and windows to ventilate the room. (b) let the fire go out or
eject and safely dispose of fuel from the appliance. (c) check the flue or
chimney for blockage and clean if required. (d) do not attempt to re-light the fire until the case of the fume emission has been identified
and corrected. If necessary seek expert advice
HEAT:
The surfaces of the appliance and the attached fluepipe will become
extremely
hot- a fireguard should be used if children or
the infirm are present. Flammable materials (including fuel) should not be stored near to the appliance. If the Europa Hi-Leg unit is
fitted and used as a log store, logs must not be placed higher than the central 'bridging' member.
BEFORE YOU BEGIN...
CHIMNEY
Your chimney creates the draught which Tiger needs in order to work - it
must
:
•
Conform to local building regulations.
•
Be at least 5m high.
•
Terminate at least 1m above any roof ridge.
•
Have an internal cross-section not less than 0.018m² (eg 150mm dia) and not more than 0.14m² (eg 375 x 375mm)
•
Be free from even the slightest crack or source of leakage.
•
Have no bends sharper than 45 degrees.
•
Be entirely free of obstructions and swept by a qualified chimney sweep.
•
Be connected only to the one appliance.
•
Have a wall thickness of at least 100mm throughout its length, or be thoroughly insulated
•
New masonry chimneys should be fitted with ceramic liners of at least 200mm diameter.
•
Prefabricated chimneys should be fully insulated, of at least 150mm internal diameter, conform to BS4543 Part 2 and be installed
in accordance with the manufacturer's instructions.
INSTALLATION CLEARANCES
The stove must be placed on a solid non-combustible hearth conforming to building regulations.
There must be no combustible material, including fuel, within: Rear 40cm, sides 30cm. If the Hi-Leg unit is fitted hearth temperature
will not exceed 100ºC, and light duty hearth material may be used.
LOAD BEARING
Tiger is heavy - take care to ensure that the floor has adequate load-bearing capacity and consider fitting a load
distributing plate if necessary
1
Conforms to EN13240
Independently tested by SGS
Arnheim, 2007
Approved Laboratory No 0608
Fuel
Wood (Beech)
Mineral Fuel
(Ancit)
Efficiency
77.90%
70.30%
Max. Output
6.2kW
6.2kW
CO Emission
(as if at 13% O2)
0.27%vol
0.13%vol
Mean Flue
Temperature
313º C
286ºC
Clearance to
combustibles
Rear 40cm
Sides 30cm
Rear 40cm
Sides 30cm
Smoke Emission
77 mg/m³
95 mg/m³
Gas flow
5.4 g/sec
6.3 g/sec
Flue Draught
Min 12Pa
Min 12Pa
THIS APPLIANCE BECOMES
EXTREMELY
HOT
AND CAN PRODUCE
POISONOUS
GASES.
A fire-guard should be used if children or the infirm are present. The
installer is required to EXACTLY follow these instructions and to
completely comply with all local, national and international standards.