The TIF XP-1A is the culmination of over 30 years of Leak Detector manufacturing
experience. TIF is proud to present this tool as the most stable and sensitive nega-
tive corona leak detector ever made. We have incorporated all of our experience,
and years of customer feedback into this product, in the hope of providing our val-
ued customers with the best of everything; price, performance and reliability.
An advanced microprocessor is the heart of this unit. Its Digital Signal Processing
permits better management of the circuitry and sensing tip signal than ever before
possible. Additionally, the number of components used in the circuit is reduced near-
ly 40%, increasing reliability and performance. The microprocessor monitors the
sensing tip and battery voltage levels 4000 times per second, compensating for
even the most minor fluctuations in signal. This translates into a stable and depend-
able tool in almost any environment.
Convenience features have been added to enhance the usability of the XP-1A.
Seven levels of sensitivity provide an increase of 64 times from level 1 to level 7.
Unique Tri-Color LED’s show a progressive and wide ranging leak size indication,
communicate the sensitivity level, and provide a true voltage indication of battery
power level. A tactile keypad controls all functions of operation. A revolutionary new
case design gives the user grip and control, and places the visual indicators in direct
sight during use.
Please take a few moments to read through the following pages, in order to under-
stand and benefit from all the capabilities of your new XP-1A. We trust that you will
be 100% satisfied with your new purchase. If you have any questions or comments
after reviewing the manual, please feel free to contact us in the USA, toll free at 1
800 327 5060 from 8AM to 5PM EST.
• Microprocessor control, with Advanced Digital Signal Processing
• Tricolor visual display
• Seven (7) levels of sensitivity provide an increase of up to 64x
• Tactile Keypad controls
• Real time sensitivity adjustment
• Battery Test function
• Battery voltage indication
• Certified to SAE J1627 for R134a, R12, R22
• Detects ALL Halogenated Refrigerants
• True mechanical pumping provides positive airflow through sensing tip
• Mute feature included
• Cordless and Portable, operates on 2 "C"-cell batteries
• Carrying case included
• 14" (35.5cm) flexible, stainless probe
• Optional Carrying Holster
• Optional Reference Leak Source
• Three Year Warranty
2
35
GENERAL INFORMATION
FEATURES
ANWENDUNGSMÖGLICHKEITEN
Der XP-1ALeckdetektor kann außerdem wie folgt verwendet werden:
•
Zur Suche nach Kühlgaslecks in Klimaanlagen, Kühlsystemen und
Vorrats-/Rückgewinnungsbehältern. Dieser Detektor reagiert auf ALLE halogen-
(chlor-, fluor-) haltigen Kühlmittel. Dazu gehören u.a.:
CFCs, z.B.: R12, R11, R500, R503 usw.
HCFCs, z.B.: R22, R123, R124, R502 usw.
HFCs, z.B.: R134a, R404a, R125 usw.
Mischungen wie AZ-60, HP62, MP39 usw.
•
Zur Suche nach Ethylenoxydgaslecks in Sterilisiergeräten in Krankenhäusern
(Erkennung von halogenisiertem Trägergas)
•
Zur Suche nach SF-6 in Hochspannungsunterbrechern
•
Zur Suche nach den meisten Gasen, die Chlor, Fluor und Brom enthalten
(Halogengase)
•
Zur Suche nach Reinigungsstoffen in Trockenreinigungsanlagen, z.B.
Perchlorethylen
•
Zur Suche nach Halongasen in Feuerlöschsystemen
WARTUNG
Es ist wichtig, daß der Leckdetektor ordnungsgemäß gewartet wird. Folgende
Anweisungen genau befolgen, um Betriebsprobleme zu verringern und die
Haltbarkeit des Geräts zu verlängern.
WARNUNG: DAS GERÄT VOR DEM REINIGEN ODER DEM AUSWECH-
SELN DER SONDENSPITZE AUSSCHALTEN. STROMSCHLAGGEFAHR!
Die Sondenspitze sauberhalten:
Die mitgelieferte Schutzkappe verwenden,
um zu verhindern, daß sich Staub, Feuchtigkeit und Fett auf der Spitze ansammeln.
Das Gerät nie ohne aufgesetzte Schutzkappe betreiben.
Vor Gebrauch des Geräts immer erst die Spitze und die Schutzkappe auf Schmutz-
und/oder Schmiermittelablagerungen untersuchen. Zum Reinigen:
1. Die Schutzkappe an der Spitze anfassen und abziehen.
2. Die Schutzkappe mit einem Tuch und/oder Druckluft reinigen.
3. Ist die Sonde selbst schmutzig, kann sie einige Sekunden lang in eine
milde Lösung getaucht werden, z.B. Alkohol. Dann mit Druckluft und/
oder einem Arbeitstuch reinigen.
HINWEIS:
Keine Lösungsmittel wie Benzin, Terpentin, Leichtbenzin usw. verwen-
den, da diese einen deutlichen Rückstand hinterlassen, der die Empfindlichkeit des
Geräts beeinträchtigt.