![TierTime UP300 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/tiertime/up300/up300_service-manual_1114576024.webp)
24
UP 300 Service Manual
Failure 19
: Platform temperature is too high
Failure
Cause
Solution
Remark
⚫
Error: platform
temperature is too
high
⚫
Software and display
terminal display
platform temperature:
About 397
°
C
⚫
This fault may occur
while the print task is
in progress
➢
Platform FFC
cable is broken,
plug is loose
Turn off the power supply, remove
the heating base plate, check if the
platform FFC cable is damaged, if the
platform FFC cable of the heating
base plate is broken, 26P cable
Remove and
replace the
platform FFC
heating cable
➢
Heating
aluminium
substrate
damaged
Turn off the power, remove the
heating aluminum substrate, check if
the heating plate has soldering short
circuit, and repair or replace
Remove and
replace the
aluminum
substrate
➢
Mainboard
damaged
Turn off the power and replace the
mainboard
➢
Platform
adapter board is
damaged
Turn off the power, replace the
platform adapter board