Failure 15:
The model displays red when clicking Print, and reports error
“Model out of print range” when transmitting
Failure
Cause
Solution
Remark
The model displays red
when sending a print task
and the error “Model out of
print range” is reported
when transmitting
➢
The model is not
automatically placed
after being scaled
and moved, and
some areas are
outside the molding
space
Set to automatically place and
retransfer the model in the software
➢
Model size out of
molding range
In the software, if you select the
model with the left mouse button,
you can know the maximum size of
the XYZ-
axis. It can’t be transferred
and printed if it exceeds the molding
space of UP 300
The forming space of UP 300 model
is X*Y*Z=205mm*255mm*225mm
➢
nozzle height value
not reasonable
Restart the machine and re-run the
height aligning
Software error
Model shows red