background image

 

9

 

Assembly 

The following describes how to assemble the Tibbo Wiegand Converter. 

 

To assemble the Tibbit: 

1

 

Insert #09 Low-power 5V supply, 12V input in S11 with the text Tibbit outside: 

  

2

 

Insert #11 four open collector outputs M1S in S1 with the text Tibbit outside: 

 

3

 

Insert #11 four open collector outputs M1S in S3 with the text Tibbit outside:  

 

Содержание Wiegand Converter

Страница 1: ...Tibbo Wiegand Converter Setup Guide For Abraxas Version 1 0 March 2019 ...

Страница 2: ...ribes the usage of the Tibbo Wiegand Converter in the Abraxas Access Control Solution and provides an overview of the workflow for setting it up CHAPTER 2 HARDWARE ASSEMBLY page 7 Describes how to assemble the hardware components of the Tibbo Wiegand Converter CHAPTER 3 FIRMWARE INSTALLATION AND SETUP page 15 Describes how to install and set up the firmware required for the Tibbo Wiegand Converter...

Страница 3: ...up Workflow 6 HARDWARE ASSEMBLY 7 Bill of Materials BoM 7 Assembly 9 Wiring 12 Covers 13 FIRMWARE INSTALLATION AND SETUP 15 Download Tibbo Firmware Tools 15 Upload the Firmware 16 Retrieve License 18 Upload the License 20 Upload the Base Firmware 22 Configuration 24 Testing 27 ...

Страница 4: ...mation in this publication and specifically disclaims implied warranties of accuracy completeness merchantability title non infringement and or fitness for a particular purpose AnyVision reserves the right to make changes in or to the said information or any part thereof in its sole judgment without the requirement of giving any notice prior to or after making such changes to the information Use c...

Страница 5: ... to your current Access Control System ACS The vast majority of ACS solutions on the market support the Wiegand protocol as their standard The Abraxas Access Control solution uses a Wiegand Converter to convert the detection and recognition information that is sent from the AnyVision engine to the ACS Various types of Wiegand Converters can be used This guide describes how to set up the Tibbo Wieg...

Страница 6: ... for the Abraxas Access Control solution 1 Bill of Materials BOM Page 7 2 Assembly Page 9 3 Wiring Page 12 4 Covers Page 13 5 Download Tibbo Firmware Tools Page 15 6 Upload the Firmware Page 16 7 Retrieve License Page 18 8 Upload the license Page 20 9 Upload the Base Firmware Page 22 10 Configuration Page 24 11 Testing Page 27 ...

Страница 7: ...omer or business partner AnyVision does not supply hardware The same BoM can also be found on Tibbo website http tibbo com store tps custom html Anyvision Wiegand G1 Table 1 BOM Quantity Image Part 1 PM01P1055 01 Bottom cover for TPB2 and TPB2L 1 PM01P1054 Top cover for TPB2 1 DMK1000 DIN Rail Mounting Kit 1 PM01P1049 Right wall for TPB all sizes 1 PM01P1050 Left wall for TPB all sizes ...

Страница 8: ...Screw For TPB all sizes Quantity 1 TPP2 G1 Size 2 Tibbo Project PCB Gen 1 1 09 Low power 5V supply 12V input 4 11 Four open collector outputs M1S Order from IDP Four open collector outputs 2 20 Nine terminal blocks C2 Order from IDP Nine terminal blocks 1 18 Power input C1 Order from IDP Power jack and two terminal blocks ...

Страница 9: ... Converter To assemble the Tibbit 1 Insert 09 Low power 5V supply 12V input in S11 with the text Tibbit outside 2 Insert 11 four open collector outputs M1S in S1 with the text Tibbit outside 3 Insert 11 four open collector outputs M1S in S3 with the text Tibbit outside ...

Страница 10: ...with the text Tibbit outside 5 Insert 11 four open collector outputs M1S in S7 with the text Tibbit outside 6 Insert 20 nine terminal blocks C2 in S2 S4 with the text Tibbit outside 7 Insert 20 Nine terminal blocks C2 in S6 S8 with the text Tibbit outside ...

Страница 11: ... Power input C1 in S12 with the text Tibbit outside 9 Insert PA PCB P2164 MD RST button PCB for TPB on top of the reset buttons rest on rest 10 Insert PM12P1001 03A C1 Tibbit shell orange blank version on S13 and S10 ...

Страница 12: ...e wired as follows Table 2 Terminal Block Ports Port Use for Value Color Tibbit 1 D0 Data White 2 3 D1 Clock Green 4 5 GND Black 6 D0 Data White 7 8 D1 Clock Green 9 1 D0 Data White 2 3 D1 Clock Green 4 5 GND Black 6 D0 Data White 7 8 D1 Clock Green 9 ...

Страница 13: ... guide for TPB in the holes 2 Insert PM01P1049 right wall for TPB in the holes 3 Insert PM01P1050 left wall for TPB in the holes 4 Close the parts together and insert the screws SM3R5 32SPBC Main screw for TPB in the holes Congratulations the stage is now done ...

Страница 14: ...14 At the end the Tibbo should look as follows ...

Страница 15: ...Wiegand Converter Download Tibbo Firmware Tools To download Tibbo firmware tools 1 Use the following link in order to download the Tibbo Device Explorer http tibbo com downloads open tide tdevexplore 5 03 04 exe 2 Use the following link in order to download the Tibbo Device Manager http tibbo com support downloads tdst html ...

Страница 16: ...d 02272019 tpc which is embedded here 02272019 tpc To upload the firmware file named 02272019 tpc 1 Click the Windows button and click the Tibbo folder Device Explorer as shown below 2 Select the Tibbo device from the list and click the Upload button ...

Страница 17: ...17 The following displays 3 Select the Load Application Through the Network option 4 Select the 02272019 tpc file and click Open as shown below 5 Click Refresh Close button as shown below ...

Страница 18: ...bbo Wiegand Converter 1 Click the Windows button and click the Tibbo folder Tibbo DS Manager 2 Choose the Tibbo device from the list and click the Settings button 3 In the Network tab configure the network parameters do not change the Local Port field ...

Страница 19: ...19 4 Click OK 5 In the General tab copy the Serial Number marked in red and submit it to AnyVision support contact person to receive a license for your Tibbo device ...

Страница 20: ...ou received The file should be named as follows Serial Number tpc To upload the license file 1 Click the Windows button and click the Tibbo folder Device Explorer as shown below 2 Select the Tibbo device from the list and click the Upload button ...

Страница 21: ...21 The following displays 3 Select the Load Application Through the Network option 4 Select the Serial Number tpc file and click Open as shown below 5 Click Refresh Close button as shown below ...

Страница 22: ...E 12052019 tpc which is embedded here tps BASE 12052019 tpc To upload the firmware file named tps BASE 12052019 tpc 1 Click the Windows button and click the Tibbo folder Device Explorer as shown below 2 Select the Tibbo device from the list and click the Upload button ...

Страница 23: ...23 The following displays 3 Select the Load Application Through the Network option 4 Select the tps BASE 12052019 tpc file and click Open as shown below 5 Click Refresh Close button as shown below ...

Страница 24: ...gand Converter 1 Click the Windows button and click the Tibbo folder Tibbo DS Manager 2 Choose the Tibbo device from the list and click the Settings button 3 In the Network tab configure the network parameters do not change the Local Port field ...

Страница 25: ...25 4 Click OK 5 In the General tab set all the Serial options Serial 1 Serial 2 Serial 3 and Serial 4 to 3 Wiegand Out as shown below Note Serial 1 is on the left side when the yellow cube is up ...

Страница 26: ...CP IP 3 and Convert TCP IP 4 For each port do the following In the Data Received field select SiteCard In the Transfer To field select W 26 or any other supported Wiegand type In the Transfer to Serial select Serial 1 for port 1 Serial 2 for port 2 Serial 3 for port 3 or Serial 4 for port 4 6 Click OK to finish The Tibbo resets and beeps after reboot ...

Страница 27: ...ty latest html 2 Run the app 3 Fill in the IP and Port 1001 fields and select Telnet 4 Click the Open button 5 Type DBG3 to go in to debug mode 6 Navigate to the browser and type the following http 192 168 20 253 command html command CON4 046 18630 http Tibbo IP command html command CON TCP_number facilty_code card_number ...

Страница 28: ... Putty displays the binary Wiegand number and the lent Wiegand bit comments on below In this case Facility Number 046 Card Number 18630 Wiegand Binary 10010111001001000110001100 It can be converted as follows 1 check bit 0010 1110 46 0100 1000 1100 0110 18630 0 check bit ...

Отзывы: