Operating manual
Servicing / Maintenance
TW63B drive
thyssenkrupp Aufzugswerke
69
Version 09/2018
8.11 Replacing the encoder
8.11.1
Removal
1.
Before starting work, switch off the power to the installation and secure against
reactivation.
2.
Unplug the encoder connection cable at the frequency inverter.
3.
Remove the central screw in the middle of the handwinding wheel hub.
4.
Pull the handwinding wheel and hub off together.
5.
Use an Allen key (2 mm) to loosen the two studs on the collar of the encoder
inner ring (do not remove).
6.
Undo and remove the screw on the bracket of the encoder mounting
7.
Remove the cable ties holding back the cables.
8.
Pull the encoder off the end of the motor shaft.
9.
Check that the technical data of the new encoder match
8.11.2 Installation
1.
Fit the encoder mount of the removed encoder onto the new encoder.
2.
Fit the clip nut of the removed motor onto the new motor, ensuring an identical
position of the 8x8 hole in the fan hood.
3.
Push the new encoder onto the clean shaft end of the motor until it makes
contact with the shaft collar and/or spring plate on the motor.
4.
The mounting collar of the encoder must point towards the shaft end.
5.
Screw on the encoder mount on the motor.
6.
Secure the encoder inner ring by tightening the stud on the motor shaft.
7.
Align the hub to axial pin in the shaft and mount the hub with handwinding
wheel by means of the central screw and disc; tighten with 75 Nm.
8.
Secure the cable by means of cable ties
Содержание TW63B
Страница 1: ...thyssenkrupp Aufzugswerke Operating manual TW63B drive...
Страница 84: ...Part No 9950 000 6021 mit 1024 Imp Part No 9950 000 6021 mit 4096 Imp...
Страница 85: ...Part No 00 990 16 03 0 with 1024 pulses...
Страница 86: ...Part No 00 990 19 03 0 mit 1024 Imp...
Страница 87: ......
Страница 103: ...Design for TW63...
Страница 104: ......