For your personal safety, read, understand and follow the information provided in this instruction manual.
THANK YOU FOR CHOOSING
THE THUNDER DC TO DC
BATTERY CHARGER
Страница 1: ...For your personal safety read understand and follow the information provided in this instruction manual THANK YOU FOR CHOOSING THE THUNDER DC TO DC BATTERY CHARGER...
Страница 2: ...Safety Warnings 5 Installation 6 Specifications 7 Integrated LED Diagram 8 Wiring Diagram 9 8 Stage Charging Mode 10 Solar Charging Mode 11 Warranty Terms Conditions Copyright 2020 GPC Asia Pacific Pt...
Страница 3: ...stage charging Pulse mode technology that reduces oxidation and minimises temperature equating to longer battery life Unit will automatically change charge rate mapping for GEL AGM and standard Lead A...
Страница 4: ...ntilation may over heat the charger and cause inefficient operation 7 If skin or clothing comes in contact with battery acid flush the affected area immediately with water Seek medical attention if ne...
Страница 5: ...e DC DC has a built in MPPT solar regulator Check all connections are tight and secure If charging a lithium battery the green battery select wire will need to be connected to battery earth see specif...
Страница 6: ...nimum 30A VEHICLE INPUT VOLTAGE RANGE 12 2V 26V If voltage increases over 26V the Thunder DC DC will shut off reset will be needed MIN AND MAXIMUM CHARGING VOLTAGES 13 1V 15 2V Stops charging when alt...
Страница 7: ...eached a loaded voltage of 12 2V the LCD screen will move to the Solar charge screen allowing you to see the main and auxiliary battery voltages main and auxiliary battery percentages and the flow of...
Страница 8: ...onises the charge algorithm to work as one unit You can add as many units as you like NOTE Only connect the Lithium charge wire Green if you intend to charge a lithium battery pack as this will cause...
Страница 9: ...nute if voltage is over 12 6V the Thunder DC DC goes to Stage 6 NOTE If battery is determined to be faulty the Thunder DC DC will stop charging 6 Stage 6 Boost Stage Voltage up to max of 15 2V dependa...
Страница 10: ...s will occur for 2 hours or until 14 5V average is reached whichever comes first Then will switch to Stage 3 3 Stage 3 Pulse floating charge pulse 1 sec on 1 sec off at 13 8V When the auxiliary batter...
Страница 11: ...the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect application i...
Страница 12: ...oria 3178 Australia 510 Mt Wellington Hwy Auckland New Zealand thunderauto com au thunderauto co nz GPC Asia Pacific 22 Enterprise Drive Rowville Victoria 3178 Australia 510 Mt Wellington Hwy Auckland...