7.3
Storage Procedures
Proper shutdown procedures must be followed to prevent pump damage. Failure to do so
may result in premature pump failure. The non-lubricated compressor is constructed of
ferrous metals and/or aluminum which are treated for corrosion protection but are still
subject to possible rust and corrosion when pumping condensable vapors such as water.
Follow the steps below to assure correct shutdown and storage between use:
1.
NEVER
oil this non-lubricated compressor as damage will result.
2. For long term storage of the ACS-517B, disconnect the air hose at outlet and
apply power allowing the compressor to run "open" for at least five minutes.
After five minutes remove power and plug/cap outlet to prevent contaminants
from entering. The ACS-517B is now ready for storage.
Warning
: All pressure MUST be vented before
disconnecting air supply hose!
7.4
Service Kit
Refer to Thomas TA series operating and maintenance manual for parts and procedures.
Thunder Scientific Corporation ACS-517B Air Compressor System
1-9
Document Number: ACS-517B.doc - Edition 06 - April 2014