Thunder Power TP1430C Скачать руководство пользователя страница 18

18 

 

Discharging Completion 

Discharging will end automatically when the battery reaches the per cell voltage cutoff set by you.  
When this occurs you will see the following screen: 
  
 
 
 
From there you can press the ENTER button once to display the data from the discharge process. 
Additionally, the +/

– buttons can be used to scroll through other screens, including the screen that 

features Battery.IR to check the Internal Resistance (IR) of the battery and/or individual cells (for 
LiPo/LiIon/LiFe and with the balancer connected). While on the Battery.IR screen, press the ENTER 
button to display the Internal Resistance values.  Or, on most other screens you can press the 
ENTER button to exit the discharge process completely. 
 

Cooling Fans During/After Discharge 
 

During the discharge process one or both fans may come on at low or high settings to help control the 
internal temperature of the charger.  In some cases, even after the discharge process has ended the 
fans will continue to run even when the internal temp has reached near ambient temperature.  If this 
happens you can power the charger off then on again and the fans will remain off until the next 
charge/discharge process begins. 
 

 
CYCLE MODE 
 

The TP1430C is capable of charging/discharging batteries automatically by cycling them up to 15 
times.  This can be particularly useful for testing and/or rejuvenating NiCd/NiMH batteries. 

Please 

note that we DO NOT recommend cycling LiPo/LiIon/LiFe batteries as it comes at great risk 
unless you monitor all charge/discharge cycles in person fully and set the discharge cutoff 
voltage to a level high enough to prevent over-discharge.  

Additionally, it has been shown that, 

unlike other chemistries such as NiCd/NiMH, it is typically not possible to rejuvenate LiPo/LiIon/LiFe 
cells/batteries through charge/discharge cycling. 
 
Please also keep in mind that aside from selecting the order of charge->discharge (CHG->DCHG) or 
discharge->charge (DCHG->CHG) and the number of cycles, you must set the chemistry type, cell 
count, capacity, and charge current rate in the Charge Mode, and the discharge current rate and the 
per cell voltage cutoff in the Discharge Mode.  After setting the correct values in the Charge Mode, 
wait until none of the adjustable values are flashing, then press the + button once to enter the 
Discharge Mode.  After setting the correct values in the Discharge mode, wait until none of the values 
are flashing then press the + button one more time to enter the Cycle Mode. 
 
 

Cycle Order 
 

You can select the cycle order, charge->discharge (CHG->DCHG) or discharge->charge (DCHG-
>CHG), by using this setting.  To change the order simply press the ENTER button once then use the 
+/ 

– buttons to adjust the order accordingly. 

 

Cycle Number 
 

 

 

Содержание TP1430C

Страница 1: ...1 SINGLE PORTHIGH POWER MULTI CHEMISTRY CHARGER DISCHARGER CYCLER BALANCING SYSTEM INSTRUCTION OPERATION MANUAL www ThunderPowerRC com...

Страница 2: ...ttery Chemistry Type 10 Battery Cell Count 11 Battery Capacity 11 Charge Current Rate 11 Balancing ON OFF for LiPo LiIon LiFe batteries 12 Delta Peak Sensitivity for NiCd NiMH batteries 13 Charging th...

Страница 3: ...Capacity Limit 22 Safety Timer 23 Temperature Cutoff 23 Key Beep 23 End Beep Duration 23 Temperature Unit 23 DATA VIEW MODE 24 Battery Internal Resistance 24 To Measure Battery Internal Resistance 25...

Страница 4: ...ttempting to charge batteries different than those specified in this manual can result in excessive heat and other related product malfunctions which can lead to property damage and or injury Please c...

Страница 5: ...ze safety charge and discharge performance Durable and compact aluminum case with dual computer controlled cooling fans and a large easy to read LCD screen Wide input voltage range from 12 0 36 0V for...

Страница 6: ...f This is the input voltage at which the charger will stop charging discharging in order to prevent overloading over discharging the input power source This is particularly beneficial when charging fr...

Страница 7: ...ount of input power your chosen power source can supply Input Voltage under load V x Input Current A Input Power W For example 12V x 25A 300W 12V x 40A 480W 24V x 25A 600W 27V x 40A 1080W The input po...

Страница 8: ...teries The balancer is marked on the faceplate label and you must ALWAYS use the balancer when charging LiPo LiIon LiFe batteries for maximum safety and battery performance longevity The balancer work...

Страница 9: ...e batteries in series and or parallel contact Thunder Power RC directly for more information on series parallel charging if needed you must NOT connect more than one battery to the balance connector a...

Страница 10: ...een simply press the ENTER button once The memory profile number will begin to flash and you can use the buttons to scroll through the profiles accordingly Battery Chemistry Type The TP1430C is capabl...

Страница 11: ...lly set a 1C 1 x Capacity charge rate In general most supported battery chemistries types can be charged safely and successfully at a 1C rate so this feature makes for the easiest possible setting and...

Страница 12: ...y throughout the Constant Voltage CV phase of the charge process and until the charge is complete Also after the charge process has started and if you have not already set the charge current rate to t...

Страница 13: ...ity value 10 20mV per cell to reach full charge while NiMH batteries require a lower value 1 10mV per cell However in the case of either chemistry the actual value that works best will depend on many...

Страница 14: ...second hundredths place after the decimal is shown due to the space available on the screen in order to show voltages for up to 8 cells on a single screen the charger is measuring and calculating the...

Страница 15: ...batteries or any combination to make a maximum of 14S at one time Example Two 6S batteries Insert the balance plugs from battery 1 in the first set of plugs marked 6S Then insert the balance plugs fro...

Страница 16: ...urrent rate to the 15 0A max for cell counts more than 2S 7 4V for LiPo LiIon LiFe and even if you do set the rate to 15 0A for higher cell batteries it will exceed the maximum discharge power level w...

Страница 17: ...perly and the charger confirms that all other parameters are correct discharging will begin automatically Data Monitoring During Discharging Throughout and after the discharge process you can view mon...

Страница 18: ...atically by cycling them up to 15 times This can be particularly useful for testing and or rejuvenating NiCd NiMH batteries Please note that we DO NOT recommend cycling LiPo LiIon LiFe batteries as it...

Страница 19: ...e current cycle by looking at the C00D info located in the middle of the upper line on the screen When the C is flashing the charger is charging and when the D is flashing the charger is discharging A...

Страница 20: ...After inputting all the correct settings as required in the Charge Mode and the Discharge Mode you can begin the storage process by simply pressing and HOLDING the ENTER button for a few seconds pleas...

Страница 21: ...charge process This value can be set for all chemistry types however you must have the chemistry you would like to set the value for selected in the Charge Mode in order for that chemistry to show ap...

Страница 22: ...rdless For Pb Lead acid batteries we suggest setting the charge end voltage to the value per cell recommended by the battery manufacturer as these values do vary from manufacturer to manufacturer Howe...

Страница 23: ...when it reaches the time limit rather than ending the charge appropriately per the chemistry type i e delta peak for NiCd NiMH CC CV to CHG End Voltage for LiPo LiIon LiFe etc especially if the batter...

Страница 24: ...lative results directly Physical Condition Age The IR will read higher in cells that are physically damaged swollen and or considerably aged and deliver less voltage and or capacity under load accordi...

Страница 25: ...batteries side by side in the same application in case the other variables affect the actual performance accordingly Unfortunately it is not really possible to create a chart that shows what a good I...

Страница 26: ...of the individual cells will not always add up to the IR value of the battery And in some cases variations in the IR values between cells can be attributed more so to their connection to the balancer...

Страница 27: ...the second hundredths place after the decimal is shown due to the space available on the screen in order to show voltages for up to 8 cells on a single screen the charger is measuring and calculating...

Страница 28: ...rom the input power source supply is too high above 36 0V This error message indicates that there is a problem with the balance connector connection and or a significant imbalance This error message i...

Страница 29: ...ctive In the event of a defect these are the Purchaser s exclusive remedies TPRC reserves the right to inspect any and all equipment involved in a warranty claim Repair or replacement decisions are at...

Страница 30: ...can be reached during business hours days along with a list of the included item s and a detailed summary regarding the Product and or issue For return of electronics including chargers balancers moto...

Страница 31: ...for more than 90 days without authorization for work or confirmation of order will be considered abandoned and may be disposed of accordingly Instructions for Disposal of WEEE by Users in the Europea...

Страница 32: ...________ _________________________________________________________________________________ _________________________________________________________________________________ ___________________________...