Chapter 2: Installation
12
Installing the Power Supply Unit and Charger
DC output (50 A) (X10)
2 x DC output (20 A) (X11 and X12)
DC output (X10)
Connector type
Cable shoe bolted to the board.
+
DC output plus
-
DC output minus
M5 in chassis
GND for drain wire (cable shield)
Fuse
One 50 A fuse plate for DC output plus. You must
use the fuse with the Thrane & Thrane part
number S-33-205377-050.
DC output (X11 and X12)
Connector type
Spring loaded terminal
Wire cross section
Up to 6 mm
2
+
DC output plus
-
DC output minus
M5 in chassis
GND for drain wire (cable shield)
GND for safety wire
Fuses
Two 20 A fuses, one for DC output plus and one
for DC output minus.
a
a. This output is rated up to 30 A, thus 30 A fuses may be used.