![ThorWorks Industries SealMaster 300 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/thorworks-industries/sealmaster-300-series/sealmaster-300-series_owners-manual_1111268008.webp)
6
HEATED ASPHALT DISTRIBUTOR
APPLIES TO ALL TRAILER AND SKID VERSIONS
OPERATING INSTRUCTIONS
PICTURE
–
1
HEATING THE MATERIAL -1
1.
Attach the threaded nipple inlet
#1
to your LP Gas tank.
The burner uses vapor propane,
NOT
liquid.
2.
Slowly open the valve on the LP Gas Tank. Opening too fast can cause a check
valve to slam closed, reducing the available flow of gas.
3.
Regulator
#3
is pre-set for 30 psi. Turn the knob counter-clockwise to lower
the pressure. The burner
#11
, is rated for maximum heat output at 30 psi.
Open gas shut-off valve
#7
slightly, depress the red push on gas pilot valve
#8
. This allows gas to flow thru the burner, at the same time use the striker
flint
#10
to produce a spark. Strike repeatedly until the gas ignites.
If the gas does not light within 5 seconds, release the red
push button and wait 10 minutes before trying again.
8
GAS PILOT
10
STRIKER FLINT
1
NIPPLE INLET
2
NUT & NIPPLE
3
REGULATOR
5
COUPLER
7
GAS SHUT-OFF
11
BURNER
9
THERMOCOUPLE
6
LP GAS HOSE
Содержание SealMaster 300 Series