background image

Rev 12 Oct 2018

Page 17

Chapter 6 Thorlabs Worldwide Contacts

Chapter 6 Thorlabs Worldwide Contacts

Thorlabs verifies our compliance with the WEEE (Waste Electrical and Electronic
Equipment) directive of the European Community and the corresponding national
laws. Accordingly, all end users in the EC may return "end of life" Annex I category
electrical and electronic equipment sold after August 13, 2005 to Thorlabs, without
incurring disposal charges. Eligible units are marked with the crossed out "wheelie
bin" logo (see right), were sold to and are currently owned by a company or institute
within the EC, and are not dissembled or contaminated. Contact Thorlabs for more
information. Waste treatment is your own responsibility. "End of life" units must be
returned to Thorlabs or handed to a company specializing in waste recovery. Do not
dispose of the unit in a litter bin or at a public waste disposal site.

USA, Canada, and South America

Thorlabs, Inc.

56 Sparta Avenue

Newton, NJ 07860

USA

Tel: 973-300-3000

Fax: 973-300-3600

www.thorlabs.com

www.thorlabs.us (West Coast)

Email: [email protected]

Support: [email protected]

Europe

Thorlabs GmbH

Hans-Böckler-Str. 6

85221 Dachau

Germany

Tel: +49-(0)8131-5956-0

Fax: +49-(0)8131-5956-99

www.thorlabs.de

Email: [email protected]

France

Thorlabs SAS

109, rue des Côtes

78600 Maisons-Laffitte

France

Tel: +33 (0) 970 444 844

Fax: +33 (0) 825 744 800

www.thorlabs.com

Email: [email protected]

Japan

Thorlabs Japan, Inc.

3-6-3 Kitamachi,

Nerima-ku, Tokyo 179-0081

Japan

Tel: +81-3-6915-7701

Fax: +81-3-6915-7716

www.thorlabs.co.jp

Email: [email protected]

UK and Ireland

Thorlabs Ltd.

1 Saint Thomas Place, Ely

Cambridgeshire CB7 4EX

Great Britain

Tel: +44 (0)1353-654440

Fax: +44 (0)1353-654444

www.thorlabs.de

email: [email protected]

Support: [email protected]

Scandinavia

Thorlabs Sweden AB

Bergfotsgatan 7

431 35 Mölndal

Sweden

Tel: +46-31-733-30-00

Fax: +46-31-703-40-45

www.thorlabs.com

Email: [email protected]

Brazil

Thorlabs Vendas de Fotônicos Ltda.

Rua Riachuelo, 171

São Carlos, SP 13560-110

Brazil

Tel: +55-16-3413 7062

Fax: +55-16-3413 7064

www.thorlabs.com

Email: [email protected]

China

Thorlabs China

Room A101, No. 100

Lane 2891, South Qilianshan Road

Putuo District

Shanghai

China

Tel: +86 (0) 21-60561122

Fax: +86 (0)21-32513480

www.thorlabschina.cn

Email: [email protected]

Содержание NRT Series

Страница 1: ...HA0136T NRT Series Motorized Translation Stage User Guide Original Instructions...

Страница 2: ...o a Work Surface 4 3 2 2 Mounting stages in X Y configurations 5 3 2 3 Mounting stages in X Y Z configurations 6 3 3 Operation 8 3 3 1 System Setup 8 3 3 2 Selecting the Stage Type 8 3 4 Calibration o...

Страница 3: ...oth translation directly driven with a hybrid 2 phase stepper motor capable of 409 600 micro steps per revolution and positioning resolutions of less than 100nm when driven by the BSC series of bencht...

Страница 4: ...ven when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruction or additional information Warning If this equipment is used...

Страница 5: ...nmental Conditions Location Indoor use only Maximum altitude 2000 m Temperature range 5oC to 40oC Maximum Humidity Less than 80 RH non condensing at 31 C To ensure reliable operation the unit should n...

Страница 6: ...working surface by M6 screws through the base To access these mounting holes turn the motor knob to move the carriage until the holes are visible through the center hole see Fig 3 1 The stage can als...

Страница 7: ...r 3 Installation and Operation 3 2 2 Mounting stages in X Y configurations Tools required 5mm hexagon key Qty 2 M6 x 12 1 4 20 UNC x 1 2 cap head bolts Engineers square and a flat plate Fig 3 2 X Y co...

Страница 8: ...that the stages are square and readjust as necessary 3 2 3 Mounting stages in X Y Z configurations 1 Fix the X axis stage to the worksurface as detailed in Section 3 2 1 2 Assemble two stages in an XY...

Страница 9: ...Rev 12 Oct 2018 Page 7 Chapter 3 Installation and Operation Fig 3 3 X Y Z configuration Z bracket assembly NRT150P1 bracket may be turned through 90 on Y stage X Y Z Side View Plan View...

Страница 10: ...These parameters relate to the physical characteristics of the stage being driven e g min and max positions leadscrew pitch homing direction etc To assist in setting these parameters correctly it is p...

Страница 11: ...from the list displayed 8 Click the Add Stage Association button 9 A default configuration is set at the factory and stored in the non volatile memory of the motor controller The server reads in the...

Страница 12: ...t up the Actuator Startup Settings window is displayed This window allows the correct actuator to be selected Fig 3 5 Stage Configuration Window 4 From the drop down menu select your NRT stage type e...

Страница 13: ...e then linked to the appropriate axis as part of the Stage association process performed using the APT Config utility Whenever the stage is moved the LUT is consulted to ascertain the precise movement...

Страница 14: ...s s Min Achievable Incremental Movement 0 1 m Absolute On Axis Accuracy 15 29 m 19 29 m Calibrated On Axis Accuracy 2 0 m 2 0 m Pitch 0 008 140 rad Yaw 0 05 873 rad Operating Temperature 20 to 40 C We...

Страница 15: ...tch Ground 9 2 Forward Limit Switch 10 3 Reverse Limit Switch 11 4 Phase B ve 12 5 Phase B ve 13 Limit Switch 5V 6 Phase A ve 14 7 Phase A ve 15 Ground 8 Part Number Description PAA612 Connection Cabl...

Страница 16: ...t harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with...

Страница 17: ...Rev 12 Oct 2018 Page 15 Chapter 5 Regulatory 5 2 CE Certificate...

Страница 18: ...Page 16 14098 D01 NRT Series Motorized Translation Stages...

Страница 19: ...st Email sales thorlabs com Support techsupport thorlabs com Europe Thorlabs GmbH Hans B ckler Str 6 85221 Dachau Germany Tel 49 0 8131 5956 0 Fax 49 0 8131 5956 99 www thorlabs de Email europe thorla...

Страница 20: ...www thorlabs com...

Отзывы: