background image

 

 

Installation

 

III.

 

 

 

Installation Requirements 

A.

1.

 

Only qualified and/or authorized persons must carry out the installation, gas conversion, and 
servicing/repair of this equipment. 

2.

 

Components having adjustments protected by the manufacturer are not to be adjusted by the 

installation person.  They must only be adjusted by an authorized service . 

3.

 

This  equipment  must  be  installed  in  an  area  with  sufficient  ventilation  to  prevent  the 

occurrence of unacceptable concentrations of substances harmful to health. 

4.

 

The  installation  of  this  equipment  must  comply  with  the  local  gas,  health,  and  safety 

requirements. 

5.

 

The  warranty  will  be  void  if  this  equipment  was  not  installed  in  accordance  with  the 
manufacturer’s specification and relevant National and Local codes. 

6.

 

This equipment must be installed in accordance with relevant National Installation codes, and 

in addition, in accordance with relevant National and Local codes covering gas and fire safety. 

 

 Australia: 

AS 5601/AG 601 (to be AS 5601)- Gas Installations 

 New Zealand: 

NZS 5261 - Gas Installation. 

 

 United Kingdom

Gas Safety (Installation and Use) Regulations 1998 
BS 6173-Installation of Catering Appliances. 
BS 5440-1&2 Installation Flueing & Ventilation. 

   Ireland: 

 

IS 820-Non Domestic Gas Installations. 

 

 

Unpack the equipment 

B.

1.

 

Remove all packaging and transit protection from the  equipment including all protective film 
coating from the  exterior stainless steel panels.    

NOTE:

   Take caution when unpacking the 

equipment,  as  wood  pallets  or  skids  can  contain  splinters  and  nails.    Shipping  cartons  can 
contain  large  staples.    Ensure  to  wear  cut-resistant  gloves  and  protective  eyewear  during 

unpacking, opening, removing and disposing of shipping containers. 

2.

 

Upon  opening  the  package,  check  immediately  the  equipment  and  accessories/parts  for  any 

damage or deficiency. 

3.

 

Upon  checking  of  the  unit,  report  immediately  to  the  carrier  and  the  distributor,  for  any 

damage or deficiency on the equipment, and its accessories or parts. 

 

Establish the location of the equipment 

C.

1.

 

This  equipment  must  be  installed  in  an  area  with  sufficient  ventilation  to  prevent  the 
occurrence of unacceptable concentrations of substances harmful to health. 

2.

 

Install the equipment in an area which will allow enough supply flow of combustion air. 

3.

 

All  air  for  burner  combustion  is  supplied  from  underneath  the  unit.    The  feet/stands  must 
always be fitted and no obstruction must be placed on the underside or around the base of the 

unit, as obstruction will cause incorrect operation and/or failure of the equipment. 

 

Содержание GL169-N

Страница 1: ...on operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in t...

Страница 2: ...troduction 3 I Specifications 4 II Installation 6 III Operation Guide 10 IV Cleaning Instructions 13 V Gas Conversion 16 VI Troubleshooting 21 VII Exploded View 22 VIII Spare Parts List 24 IX Declarat...

Страница 3: ...out by a competent service person to ensure correct and safe operation of your equipment is maintained c Do not spray aerosols in the vicinity of this equipment while it is in operation d The equipme...

Страница 4: ...rners 2 It is fitted with full pilot and flame failure protection Pack Contents B The following are included 1 Thor Gas Hob 2 Gas Stand 3 Instruction Manual 4 Conversion kit for Propane for GL169 P un...

Страница 5: ...er injector Orifice Injector Mark Orifice Size in mm 44 2 18 53 1 51 54 1 40 54 1 40 FDS injector Pilot injector Injector Mark Orifice Size in mm 45 0 45 25 0 25mm 25 0 25mm 25 0 25mm Burner Air Shutt...

Страница 6: ...1 2 Installation Flueing Ventilation Ireland IS 820 Non Domestic Gas Installations Unpack the equipment B 1 Remove all packaging and transit protection from the equipment including all protective fil...

Страница 7: ...and level The installation of the gas stand should be carried out before the completion of the gas connection Install the gas stand D 1 Remove the Stand from the packaging ensuring that all protectiv...

Страница 8: ...ted on its rating label Ensure that adequate supply pressure exists 4 When a supply regulator is to be installed ensure that the supply regulator is converted to the correct gas type that the equipmen...

Страница 9: ...requirement turn OFF the burner and pilot shut off the isolation gas valve and remove the portable manometer from the Manifold Pressure Test Point and return the plug Then check for gas leak after re...

Страница 10: ...ponents that have adjustments which are protected by the manufacturer or his agents shall not be adjusted by the user operator 3 Please use woks with a diameter between 240mm to 280mm Equipment Contro...

Страница 11: ...lot burner should stay lit if not repeat Steps 1 to 3 above 5 If pilot burner was extinguished during normal operation wait for 5 minutes before lighting it up Lighting the Main Burners C 1 Select the...

Страница 12: ...e adjusted by the user operator 2 The space between the legs at the bottom admits combustion air DO NOT BLOCK THIS SPACE 3 All burners are lit from constantly burning pilots Turning the valve to the d...

Страница 13: ...eaning material had been completely removed after each cleaning Daily Cleaning B 1 Trivets and Burners a Remove the trivet s from the equipment b The burner can be cleaned in its place c Scrape off th...

Страница 14: ...ake caution when removing or handling them since these parts are heavy and can cause injury when they fall on your toe or foot f Once the burner is thoroughly dry install the burner in place Ensure th...

Страница 15: ...rocedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and furt...

Страница 16: ...embly connection to the safety gas valve Then turn the main pipe assembly towards you for easy access to the main burner injector f Remove and replace the main burner injector using 13mm spanner Ensur...

Страница 17: ...t Pilot Injector Refer to the Gas Specification Table on page 5 of this manual for the corresponding Pilot Injector size for the specific gas type that the unit will operate on d Reconnect the pilot p...

Страница 18: ...e height of the low flame by rotating the screw counter clockwise to increase and clockwise to decrease 4 Check the connections for gas leak Use soapy water or any gas leak detecting solution to check...

Страница 19: ...nd other burner flame abnormalities 13 Refit the pilot covers radiants cast grates front panel cover and knobs 14 After converting the unit ensure to post the new label with the appropriate gas type u...

Страница 20: ...20 20 44 2 18mm 0 45 8 8 BE FR I2E G20 20 20 44 2 18mm 0 45 8 8 BE CH CZ IT ES FR GR GB HR LT NL PT SK IE SI I3P 37 G31 37 37 53 1 51mm 0 25 8 8 AT CH CZ DE DK FI FR GB GR IT NL NO SE I3B P G30 30 30...

Страница 21: ...burner does not light Pilot burner is not lit Light the pilot burner first Not enough gas or gas pressure Check the gas tank Ensure that it is not empty Check the gas pressure Ensure that you have su...

Страница 22: ...22 Exploded View VIII 5 6 14 2 3 4 11 13 1 8 9 7 10 12...

Страница 23: ...23 Exploded View 26 27 28 24 15 17 19 20 21 25 23 22 16 18...

Страница 24: ...37 1 1 9 Copper Joint 01 02 1005351 1 1 10 Burner support 06 05 1471836 2 2 11 Heating insulation 01 05 1028912 2 2 12 Drip tray 01 05 1028914 1 1 13 Gas stand 1 SET 07 18 28 1590980 1 1 14 Foot fix p...

Страница 25: ...jector Orifice for Natural Gas 44 01 20 1068644 4 22 Pilot pipe assembly Rear 01 24 1070904 2 2 23 Pilot pipe assembly Front 01 24 1070903 2 2 24 Safety Valve For Natural Gas Includes 1 6mm bypass scr...

Страница 26: ...26 Declaration of Conformity X...

Страница 27: ...27...

Страница 28: ...28 Fourth Way Avonmouth Bristol BS11 8TB United Kingdom Ver 2 Rev 0 2016 05...

Отзывы: