background image

 

 

Introduction 

I.

 

 

 

CE Only: 

 
These instructions are only valid if the country code appears on the appliance.  If the code does not 
appear  on  the  appliance,  refer  to  the  supplier/distributor  of  this  appliance  to  obtain  the  technical 
instructions for adapting the appliance to the conditions for use in that country. 

 
 

VERY IMPORTANT!   READ THIS FIRST  
 

Before  installing  and  operating  this  equipment,  ensure  that  everyone  involved  in  its  operation  are 
fully trained and are aware of all precautions.  Accidents and problems can  result from a  failure to 
follow fundamental procedures and correct operation. 

 

 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 

IMPORTANT REMINDER! 

 

Care must be taken by the operator to use the equipment safely, and to guard it against risk 

of fire.  The following precautions must be adhered to: 
 

a. The equipment must not be left unattended, while it is in operation. 

 

b. It  is  recommended  that  a  regular  inspection  is  carried  out  by  a  competent  service 

person to ensure correct and safe operation of your equipment is maintained. 

 

c. Do not spray aerosols in the vicinity of this equipment while it is in operation. 

 

d. The equipment must not be operated without the feet/gas stand fitted. 

CAUTION! 

 

To avoid property damage, personal injury or death, all gas joints and connections disturbed 
during servicing, repair, gas conversion, and installation, must be checked for gas leaks.  Use 
only gas leak detecting solutions or  soap and  water solution (bubble test) to  check for gas 
leaks. Do not use naked flame to check for gas leaks. 

CAUTION! 

This  commercial  cooking  equipment  is  for  professional  use  and  shall  be  used  by  qualified 
persons. 

Congratulations on your new THOR Gas Hob!  You will be pleased with your THOR Gas Hob, and to 
make sure that you get the most benefit from it, you must first read the Installation and Operation 
Manual. Please  contact  your  dealer  or  distributor  if  you  are  not  sure  about  any  aspect  of  the 
installation, instruction or the performance of your equipment.  They will be very glad to assist you. 

Содержание GL169-N

Страница 1: ...on operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in t...

Страница 2: ...troduction 3 I Specifications 4 II Installation 6 III Operation Guide 10 IV Cleaning Instructions 13 V Gas Conversion 16 VI Troubleshooting 21 VII Exploded View 22 VIII Spare Parts List 24 IX Declarat...

Страница 3: ...out by a competent service person to ensure correct and safe operation of your equipment is maintained c Do not spray aerosols in the vicinity of this equipment while it is in operation d The equipme...

Страница 4: ...rners 2 It is fitted with full pilot and flame failure protection Pack Contents B The following are included 1 Thor Gas Hob 2 Gas Stand 3 Instruction Manual 4 Conversion kit for Propane for GL169 P un...

Страница 5: ...er injector Orifice Injector Mark Orifice Size in mm 44 2 18 53 1 51 54 1 40 54 1 40 FDS injector Pilot injector Injector Mark Orifice Size in mm 45 0 45 25 0 25mm 25 0 25mm 25 0 25mm Burner Air Shutt...

Страница 6: ...1 2 Installation Flueing Ventilation Ireland IS 820 Non Domestic Gas Installations Unpack the equipment B 1 Remove all packaging and transit protection from the equipment including all protective fil...

Страница 7: ...and level The installation of the gas stand should be carried out before the completion of the gas connection Install the gas stand D 1 Remove the Stand from the packaging ensuring that all protectiv...

Страница 8: ...ted on its rating label Ensure that adequate supply pressure exists 4 When a supply regulator is to be installed ensure that the supply regulator is converted to the correct gas type that the equipmen...

Страница 9: ...requirement turn OFF the burner and pilot shut off the isolation gas valve and remove the portable manometer from the Manifold Pressure Test Point and return the plug Then check for gas leak after re...

Страница 10: ...ponents that have adjustments which are protected by the manufacturer or his agents shall not be adjusted by the user operator 3 Please use woks with a diameter between 240mm to 280mm Equipment Contro...

Страница 11: ...lot burner should stay lit if not repeat Steps 1 to 3 above 5 If pilot burner was extinguished during normal operation wait for 5 minutes before lighting it up Lighting the Main Burners C 1 Select the...

Страница 12: ...e adjusted by the user operator 2 The space between the legs at the bottom admits combustion air DO NOT BLOCK THIS SPACE 3 All burners are lit from constantly burning pilots Turning the valve to the d...

Страница 13: ...eaning material had been completely removed after each cleaning Daily Cleaning B 1 Trivets and Burners a Remove the trivet s from the equipment b The burner can be cleaned in its place c Scrape off th...

Страница 14: ...ake caution when removing or handling them since these parts are heavy and can cause injury when they fall on your toe or foot f Once the burner is thoroughly dry install the burner in place Ensure th...

Страница 15: ...rocedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and furt...

Страница 16: ...embly connection to the safety gas valve Then turn the main pipe assembly towards you for easy access to the main burner injector f Remove and replace the main burner injector using 13mm spanner Ensur...

Страница 17: ...t Pilot Injector Refer to the Gas Specification Table on page 5 of this manual for the corresponding Pilot Injector size for the specific gas type that the unit will operate on d Reconnect the pilot p...

Страница 18: ...e height of the low flame by rotating the screw counter clockwise to increase and clockwise to decrease 4 Check the connections for gas leak Use soapy water or any gas leak detecting solution to check...

Страница 19: ...nd other burner flame abnormalities 13 Refit the pilot covers radiants cast grates front panel cover and knobs 14 After converting the unit ensure to post the new label with the appropriate gas type u...

Страница 20: ...20 20 44 2 18mm 0 45 8 8 BE FR I2E G20 20 20 44 2 18mm 0 45 8 8 BE CH CZ IT ES FR GR GB HR LT NL PT SK IE SI I3P 37 G31 37 37 53 1 51mm 0 25 8 8 AT CH CZ DE DK FI FR GB GR IT NL NO SE I3B P G30 30 30...

Страница 21: ...burner does not light Pilot burner is not lit Light the pilot burner first Not enough gas or gas pressure Check the gas tank Ensure that it is not empty Check the gas pressure Ensure that you have su...

Страница 22: ...22 Exploded View VIII 5 6 14 2 3 4 11 13 1 8 9 7 10 12...

Страница 23: ...23 Exploded View 26 27 28 24 15 17 19 20 21 25 23 22 16 18...

Страница 24: ...37 1 1 9 Copper Joint 01 02 1005351 1 1 10 Burner support 06 05 1471836 2 2 11 Heating insulation 01 05 1028912 2 2 12 Drip tray 01 05 1028914 1 1 13 Gas stand 1 SET 07 18 28 1590980 1 1 14 Foot fix p...

Страница 25: ...jector Orifice for Natural Gas 44 01 20 1068644 4 22 Pilot pipe assembly Rear 01 24 1070904 2 2 23 Pilot pipe assembly Front 01 24 1070903 2 2 24 Safety Valve For Natural Gas Includes 1 6mm bypass scr...

Страница 26: ...26 Declaration of Conformity X...

Страница 27: ...27...

Страница 28: ...28 Fourth Way Avonmouth Bristol BS11 8TB United Kingdom Ver 2 Rev 0 2016 05...