Specifications
General
Stainless steel enclosure
All burners have flame safeguard
The valve is the modulating thermostat with on/off function with temperature selecting knob
Cast iron burner
Thermostat with manual reset limit switch
Three/four burner; Three/four combustion tube
Oil Tank size14"*14"
Pack Contents
The following is included:
Gas Fryer
Castors
Instruction
Fryer Restraint Chain
Gas Supply Requirements
Natural Gas(G20)
Propane(G31)
Butane(G30)
GL165-N
GL166-N
GL165-P
GL166-P
GL165-P
GL166-P
Single burner Heat Input
8.8 KW
8.8 KW
8.8 KW
8.8 KW
8.8 KW
8.8 KW
Heat Total
26.4KW
35.2 KW
26.4KW
26.4KW
35.2 KW
26.4KW
Burner Operating
17 mbar
14 mbar
36 mbar
34 mbar
27-29 mbar
Supply Pressure
20 mbar
37 mbar
28-30 mbar
Gas Connection
¾” BSP Male
¾” BSP Male
¾” BSP Male
The burner operating pressure is to be measured at the gas control valve outlet test point with one burner
operating at ‘High’ setting. The operating pressure is ex-factory set, through the appliance regulator and not
to be adjusted.