HARD WIRE PRODUCT INSTALLATION GUIDE FOR DRM1050 AND DRM750 RIPPLE FILTER 
INCLUDING AN EXAMPLE OF INSTALLATION IN SERIES WITH A DRM95-20A. 
 

  

 

 

 

 
 
DISCLAIMER:  
 

This guide has been compiled as a connection guide only for Thor Technologies Ripple Filter 
DRM1050 & DRM750. In addition, and as an option, if it is wired in Series with Thor Technologies 
Mains Filtered Surge Protection product DRM95-20A, an example of how to connect is outlined.  
It is not a guide or instruction for the configuration/orientation of a switchboard or any of the 
fittings used therein.  
 
The important parts are highlighted in the wiring diagrams for the Thor Technologies DRM1050 & 
DRM750 and if a DRM95-20A is used.  
 
Each CB*/RCD*/RCBO has some variations as to the wiring. Please read the instructions of the safety 
device before installing with a DRM1050 or DRM750 and a DRM95-20A. The maximum current 
allowable for the safety device to be used is 10A as the Ripple Filter Maximum current load is 10A. 
 
All wiring must be carried out by a licensed electrician and all work is subject to regulations in each 
state or territory.  
 
 

Special instructions for all Thor Technologies hardware products

:  

 
The neutral connection output from the Thor Technologies hardware product like the Ripple Filter or 
DRM95-20A must be used as a totally isolated neutral out for the circuit being protected/filtered 
output.   
 

Do not return the Neutral out from the Ripple Filters or from the DRM95-20A to the common Neutral 
Bar in the switchboard or

 

cross wire into existing circuits where that circuit’s neutral is returned to 

the common neutral bar at the switchboard. Doing so will cause the product to overheat and 
subsequently fail. If wired incorrectly with continuous current draw it may cause the casing to melt 
or lead to other major problems.  
 
Installer created or existing problems are not covered by Thor Technologies product warranties 
written, implied or otherwise.  
 
THE Ripple Filter Circuit and the DRM95-20A circuit if used should be totally independent and 
isolated.  
 
All drawings subject to change without notice.  