background image

 

MANUAL PART NO. 04-049758-002 Rev. 2
MARCH 07, 2003 

INSTALLATION MANUAL

 

TRITON routing switcher

 

Single-Bus Control Panel 16x1 

Product model no. TTN-CP-1601 

the most watched worldwide

 

 

 

Содержание Grass Valley Triton

Страница 1: ...MANUAL PART NO 04 049758 002 Rev 2 MARCH 07 2003 INSTALLATION MANUAL TRITON routing switcher Single Bus Control Panel 16x1 Product model no TTN CP 1601 the most watched worldwide...

Страница 2: ...Broadcast and Media Solutions Inc All rights reserved Grass Valley Jupiter and Triton are trademarks of Thomson Specifications subject to change without notice For customer service please call 800 54...

Страница 3: ...NCB connection 4 4 1 Control bus structure 4 4 2 Maximum distance between NCB devices 4 4 3 Several routers in one system 4 4 4 Connecting control panels 4 4 5 Pin out and cable type 5 4 5 1 RJ45 con...

Страница 4: ...of the art suppression of electromagnetic radiation This equipment in production before October 1 1981 has not been tested to the above listed measurements However equipment such as this delivered aft...

Страница 5: ...ull stock of replacement parts available for immediate shipment NORTH AMERICA PARTS AND SERVICE Please call toll free 1 800 547 8949 You will be switched automatically to the parts and service represe...

Страница 6: ...evision of this document is the uppermost in the table below Revision Replaces Date Change Description 2 1 06 03 03 Updated with new Thomson GVG design 1 0 30 01 01 Corrected error in baud rate settin...

Страница 7: ...in the button On the left hand side the panel provides 4 function keys with following functions TAKE Executes the last operation TAKE ON OFF Enables disables Take function AUDIO VIDEO Enables Audio Vi...

Страница 8: ...he CP 1601 is normally delivered with the desktop power model AC 5V 10W Upon customer request CP 1601 can also be delivered with DC 5V 30W which may be fed by a 36 72 VDC mains power source A Frame mo...

Страница 9: ...hapter 5 for more information All panels and routers are delivered with default level 1 Triton Router Control System offers the control of up to 16 different levels of routers or combinations of route...

Страница 10: ...tion The total number of Triton devices in an NCB chain is limited to 20 4 2 Maximum distance between NCB devices The standard MIDI definition allows a maximum cable length of 250 meters between two d...

Страница 11: ...Pin 7 Not Connected Pin 8 Not Connected 4 5 2 5 pin DIN connectors However on Triton devices that use MIDI connectors to connect to the NCB these connectors follow the standard MIDI specification A 1...

Страница 12: ...VS 1616 and a BVS 0808 on the same level If they were on the same level crosspoint commands that were sent to the BVS 1616 lying outside the range of the BVS 0808 would not be executed the BVS 0808 wo...

Страница 13: ...CP 1601 Rev 2 7 Triton RCS Complete the Control loop by connecting all Control bus connections to all Triton devices before powering up any Triton device...

Страница 14: ...a specific router have to be configured to the same level Note that although the Triton routers may be configured up to 16 levels the Triton control panels may only be configured up to 8 levels Level...

Страница 15: ...3 are not in use for this product Switches 4 8 on the configuration switch define the router output for the control panel The outputs can be switched according to the following pattern means switch O...

Страница 16: ...y blinking Panel Enable and Take All the legal inputs for the selected output are shown by orange light in button The Legal Illegal toggle is done by pushing the appropriate input button When a new ou...

Страница 17: ...he crosspoint operation will be executed when pressing the input button The panel updates the button after receiving an acknowledge message from the router If the acknowledge is missing the button wil...