background image

Individual Cat. No

54151CFB-BHL............... New Work Bar Hanger with 1-1/2" Deep Box. (Metallic Ceiling Fan Box)

WARNING

DISCONNECT THE ELECTRICAL CIRCUIT SUPPLYING POWER  

TO THE OUTLET PRIOR TO INSTALLATION.

CAUTION

TO PREVENT INJURY, THE HANGER MUST BE SECURELY 
INSTALLED IN ACCORDANCE WITH THESE INSTRUCTIONS 
BEFORE MOUNTING OR CONNECTING A CEILING FAN OR 
LIGHT FIXTURE.

AFTER INSTALLATION OF THE HANGER, BE SURE TO 
FOLLOW ALL MOUNTING INSTRUCTIONS WITH THE CEILING 
FAN OR LIGHT FIXTURES.

READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE PROCEEDING!

INSTALLATION INSTRUCTIONS:

TA04763  D    Page 1 of 2

NEW WORK CEILING FAN

AND LIGHT FIXTURE BAR HANGER

INSTRUCTION SHEET

Figure 1

1. Expand the bar hanger to the length of spacing between the wood 

ceiling joists. If the drywall is 1/2" thick, the locating tabs on the 
end-plates can be used to position the hanger. If the drywall is 
thicker than 1/2", the locating tabs need to be broken off and the 
end plate is positioned to make the bottom of box flush with 
drywall. (See Figure 1).

END-PLATE

Reference drywall flush with bottom of box.

LOCATING
TAB

—CONSULT A QUALIFIED ELECTRICIAN IF YOU HAVE ANY QUESTIONS. —

IMPORTANT SAFETY NOTICE:  

USE ONLY METALLIC BOX AND SCREWS PROVIDED IN KIT.  DO NOT SUBSTITUTE! 

  

CAUTION

DO NOT EXCEED MAXIMUM WEIGHT RATINGS

FOR 16” SPANS
MAX LIGHT FIXTURE = 200 LBS.
MAX CEILING FAN = 70 LBS.

FOR 24” SPANS
MAX LIGHT FIXTURE = 90 LBS.
MAX CEILING FAN = 70 LBS.

INSTALL THIS BAR HANGER SUPPORT ONLY IN 
ACCORDANCE WITH APPLICABLE NATIONAL AND LOCAL 
BUILDING AND ELECTRICAL CODES.