Содержание TSA 1400

Страница 1: ...TSA 4 700 TSA 1400 TSA 2200 TSA 4000 TSA 4 300 TSA 4 1300 power amplifier user manual...

Страница 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 25 02 2014 ID 218912 218913 218915 287602 325986 V2...

Страница 3: ...s 6 2 Safety notes 9 3 Features 14 4 Installation and starting up 15 5 Connections and operating elements 16 6 Current consumption 32 7 Technical specifications 36 8 Plug and connection assignment 46...

Страница 4: ...s and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this m...

Страница 5: ...function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For...

Страница 6: ...s in this manual are identified by an arrow and the specified page number In the electronic version of the manual you can click the cross reference to jump to the specified location Example See Cross...

Страница 7: ...bol and signal word indicates a possible dangerous situation that can result in minor injury if it is not avoided NOTICE This combination of symbol and signal word indicates a possible dangerous situa...

Страница 8: ...Warning signs Type of danger Warning danger zone General information power amplifier 8...

Страница 9: ...nd intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety...

Страница 10: ...er serviceable parts inside DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord with a pro tective contact plug Do not modify the mains cable...

Страница 11: ...ge Decrease the volume level immediately if you experience ringing in your ears or hearing impairment If this is not possible keep a greater distance or use suffi cient ear protectors NOTICE Risk of f...

Страница 12: ...nnecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could re...

Страница 13: ...wer amplifier Therefore never place sensitive devices such as pre amplifiers radio transmission systems or tape decks directly above or below the power amplifier When installing the power amplifier in...

Страница 14: ...sockets n protective circuits audio limiter thermal protection short circuit protection n 19 rack mountable 2 RU Find device specific features here Chapter 5 Connections and operating elements on page...

Страница 15: ...vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Establish all connections as long...

Страница 16: ...5 Connections and operating elements Front panel TSA 4 700 Connections and operating elements power amplifier 16...

Страница 17: ...A to D The LED Power lights permanently during operation The LEDs Signal 20 15 10 5 respond to the input signal If any of these LEDs are lit without an input signal is present disconnect the speakers...

Страница 18: ...Rear panel TSA 4 700 Connections and operating elements power amplifier 18...

Страница 19: ...modes Stereo channels operate independently of each other and Bridge two channels are interconnected to form one channel with double output 8 Push button Lift Ground Use the Ground Lift switch to sepa...

Страница 20: ...Front panel TSA 1400 2200 4000 Connections and operating elements power amplifier 20...

Страница 21: ...nd B The LED Power lights permanently during operation The LEDs Signal 20 15 10 5 respond to the input signal If any of these LEDs are lit without an input signal is present disconnect the speakers fr...

Страница 22: ...Rear panel TSA 1400 2200 4000 Connections and operating elements power amplifier 22...

Страница 23: ...es Stereo channels operate independently of each other and Bridge two channels are interconnected to form one channel with double output 8 Push button Lift Ground Use the Ground Lift switch to separat...

Страница 24: ...Front panel TSA 4 300 Connections and operating elements power amplifier 24...

Страница 25: ...to D The LED Power lights permanently during operation The LEDs Signal 20 15 10 5 respond to the input signal If any of these LEDs are lit without an input signal is present disconnect the speakers fr...

Страница 26: ...Front panel TSA 4 1300 Connections and operating elements power amplifier 26...

Страница 27: ...to D The LED Power lights permanently during operation The LEDs Signal 20 15 10 5 respond to the input signal If any of these LEDs are lit without an input signal is present disconnect the speakers fr...

Страница 28: ...Rear panel TSA 4 300 TSA 4 1300 Connections and operating elements power amplifier 28...

Страница 29: ...itch position the signals are fed separately to the power amps In the lower switch position the signals are added and fed as a mono sum signal to the power amps The connection of the power amps is set...

Страница 30: ...ion of switch A 8 are being amplified in stereo mode and separately fed to outputs A and B The volume for output A and output B can be controlled separately with the controls for channel A or B 3 Wiri...

Страница 31: ...he volume for output C and output D can be controlled separately with the controls for channel C or D 3 Wiring of the NL4 output sockets Plus terminal 1 minus terminal 1 n Push button is pushed Both p...

Страница 32: ...he data must be multiplied by factor 0 96 with 120 V by factor 1 83 and with 100 V by factor 2 2 TSA 4 700 Load 1 8 power pink noise 1 3 power pink noise Full power sine wave 4 8 400 W 3 1 A 860 W 5 8...

Страница 33: ...1 A 1313 W 7 2 A 3345 W 17 3 A 8 bridged 500 W 3 0 A 1200 W 6 9 A 2300 W 12 4 A 4 bridged 984 W 5 4 A 2690 W 14 2 A 3310 W 17 2 A TSA 2200 Load 1 8 power pink noise 1 3 power pink noise Full power si...

Страница 34: ...1200 W 6 8 A 2850 W 15 2 A 4 bridged 820 W 4 5 A 1900 W 10 1 A 4600 W 23 A TSA 4000 Load 1 8 power pink noise 1 3 power pink noise Full power sine wave 2 8 475 W 3 7 A 974 W 6 8 A 2732 W 17 A 2 4 708...

Страница 35: ...7 A 2 8 bridged 706 W 5 6 A 1847 W 13 1 A 3438 W 22 8 A TSA4 1300 Load 1 8 power pink noise 1 3 power pink noise Full power sine wave 4 8 1050 W 7 5 A 2920 W 18 7 A 6503 W 39 4 A 4 4 1580 W 10 7 A 42...

Страница 36: ...W Max output power bridged THD 1 1 kHz 2 1600 W 2 1800 W Max voltage swing RMS THD 1 1 kHz 62 6 V Slew rate 1 kHz 38 V ms THD 0 1 IMD SMPTE 60 Hz 7 kHz 0 1 DIM 30 3 15 kHz 15 kHz 0 1 Crosstalk ref 1 k...

Страница 37: ...nal to noise ratio 105 dB A weighted Protective circuits Temperature short circuit limiter Cooling front to rear Operating supply voltage AC 230 V 50 60 Hz Power consumption see Chapter 6 Current cons...

Страница 38: ...power bridged THD 1 1 kHz 2 1380 W 2 1600 W Max voltage swing RMS THD 1 1 kHz 60 V Slew rate 1 kHz 35 V ms THD 0 1 IMD SMPTE 60 Hz 7 kHz 0 1 DIM 30 3 15 kHz 15 kHz 0 1 Crosstalk ref 1 kHz 10 rated pow...

Страница 39: ...nal to noise ratio 105 dB A weighted Protective circuits Temperature short circuit limiter Cooling front to rear Operating supply voltage AC 230 V 50 60 Hz Power consumption see Chapter 6 Current cons...

Страница 40: ...power bridged THD 1 1 kHz 2 1800 W 2 2400 W Max voltage swing RMS THD 1 1 kHz 68 7 V Slew rate 1 kHz 41 V ms THD 0 1 IMD SMPTE 60 Hz 7 kHz 0 1 DIM 30 3 15 kHz 15 kHz 0 1 Crosstalk ref 1 kHz 10 rated p...

Страница 41: ...nal to noise ratio 105 dB A weighted Protective circuits Temperature short circuit limiter Cooling front to rear Operating supply voltage AC 230 V 50 60 Hz Power consumption see Chapter 6 Current cons...

Страница 42: ...0 W THD 0 5 IMD SMPTE 60 Hz 7 kHz 0 35 Crosstalk at 1 kHz 75 dB at 20 kHz 58 dB Frequency response 1 W 20 Hz 20 kHz 0 1 dB Input impedance 20 k balanced 10 k unbalanced Input sensitivity rated power o...

Страница 43: ...e Cooling Internal heat dissipation with forced ventilation through con trolled fan overheating protection Ventilation front to rear Operating supply voltage AC 230 V 50 60 Hz Power consumption see Ch...

Страница 44: ...00 W THD 0 5 IMD SMPTE 60 Hz 7 kHz 0 35 Crosstalk at 1 kHz 75 dB at 20 kHz 58 dB Frequency response 1 W 20 Hz 20 kHz 0 1 dB Input impedance 20 k balanced 10 k unbalanced Input sensitivity rated power...

Страница 45: ...Cooling Internal heat dissipation with forced ventilation through con trolled fan overheating protection Ventilation front to rear Operating supply voltage AC 230 V 50 60 Hz Power consumption see Cha...

Страница 46: ...ors one core plus shielding are typical representatives of the unbalanced transmission One conductor is ground and shielding while the signal is trans mitted through the core Unbalanced transmission i...

Страница 47: ...ompletely neutralized The result is a pure signal without any noise inter ference 1 Ground shielding 2 Signal in phase 3 Signal out of phase 1 Ground shielding 2 Signal 3 Bridged to pin 1 XLR plug bal...

Страница 48: ...1 Signal 1 in phase 1 Signal 1 180 degree phase shift 2 Signal 2 in phase 2 Signal 2 180 degree phase shift NL4 mounting connectors Plug and connection assignment power amplifier 48...

Страница 49: ...to remove dust and dirt Before cleaning switch off the device and disconnect AC powered devices from the mains Use a lint free damp cloth for cleaning Never use solvents or alcohol for cleaning Fan gr...

Страница 50: ...lease follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste Di...