background image

Notes

 

 

Retro Flat Par 18x10W RGBWA UV, 18x12W RGBW

69

Содержание STAIRVILLE 18x10W RGBWA UV

Страница 1: ...Retro Flat Par 18x10W RGBWA UV 18x12W RGBW LED PAR user manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 08 02 2017 ID 404358 404364...

Страница 3: ...structions 12 3 Features 17 4 Installation 18 5 Starting up 22 6 Connections and controls 25 7 Operating 28 7 1 Operating mode Manual 29 7 2 Operating mode Auto Run Mode 32 7 3 Operating mode Sound Mo...

Страница 4: ...358 51 7 12 Functions in 10 channel DMX mode Retro Flat Par 18x10W RGBWA UV item no 404358 52 7 13 Functions in 4 channel DMX mode Retro Flat Par 18x12W RGBW item no 404364 56 7 14 Functions in 6 chan...

Страница 5: ...11 Cleaning 66 12 Protecting the environment 67 Table of contents Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 5...

Страница 6: ...tions and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives th...

Страница 7: ...the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consul...

Страница 8: ...entions The letterings for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks...

Страница 9: ...arrow Example 1 Switch on the device 2 Press Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbo...

Страница 10: ...ion of symbol and signal word indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a po...

Страница 11: ...Warning signs Type of danger Warning danger zone General notes Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 11...

Страница 12: ...ating con ditions is considered to be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by...

Страница 13: ...t They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high voltage...

Страница 14: ...ure to do so could result in electric shock death or fire If in doubt seek advice from a regis tered electrician WARNING Eye damage caused by high light intensity Never look directly into the light so...

Страница 15: ...Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or moisture Avoid direct s...

Страница 16: ...and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms...

Страница 17: ...device n Retro Flat Par 18x10W RGBWA UV item no 404358 18 6 in 1 LEDs 10 W each Retro Flat Par 18x12W RGBW item no 404364 18 4 in 1 LEDs 12 W each n Control via DMX three different modes via buttons...

Страница 18: ...transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the...

Страница 19: ...ys be below 40 C 104 F NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum p...

Страница 20: ...or output to audio devices such as mixers or ampli fiers Please note that this device must not be connected to a dimmer You can install the unit in hanging or standing position When in use the device...

Страница 21: ...whenever installing moving or servicing the unit In doing so the area underneath the unit must be cordoned off Additionally secure the device by a safety rope against falling Installation Retro Flat...

Страница 22: ...ting up Create all connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards Starting up LED P...

Страница 23: ...Connect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated with a r...

Страница 24: ...synchronized show This function is ideal when you want to start a show immediately Connect the DMX output of the master device to the DMX input of the first slave device Then connect the DMX output o...

Страница 25: ...6 Connections and controls Connections and controls Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 25...

Страница 26: ...ne 4 DMX Out DMX output 5 Fuse holder Should the fuse have blown disconnect the unit from the power supply and replace the fuse with a new fuse of the same type 6 Power Out Lockable powerCON output so...

Страница 27: ...n DMX input 10 Down Decreases the displayed value by one 11 Locking screws for the mounting brackets 12 Mode Activates the main menu saves changes 13 Infrared sensor for the signals of an IR remote co...

Страница 28: ...de to activate the main menu and select an operating mode Use Setup to select further options Use Up and Down to change the respectively indicated value Use Setup to confirm the selection The display...

Страница 29: ...s only relevant if the device is not con trolled via DMX 1 Press Mode use Up and Down to select the menu item PROGRAM and confirm with Setup 2 Use Up and Down to select the desired programme 01 14 and...

Страница 30: ...ng for all LEDs see the following chart Colour Display Retro Flat Par 18x10W RGBWA UV item no 404358 Retro Flat Par 18x12W RGBW item no 404364 Blackout Black Black Red Red Red Green Green Green Blue B...

Страница 31: ...an Cyan Cyan Light red Light Red Light Red Light green Light Green Light Green Light blue Light Blue Light Blue Warm white Warm White Warm White Cold white Cold White Cold White After selecting progra...

Страница 32: ...with Up and Down in a range from 000 99 slow fast 7 2 Operating mode Auto Run Mode This operating mode can only be activated when the unit is operating in stand alone mode or as master in a master sl...

Страница 33: ...select the menu item SOUND and confirm with Setup 2 Set the sensitivity of the built in microphone with Up and Down in a range from 00 31 minimum maximum sensitivity and confirm with Setup The unit w...

Страница 34: ...llows the Master s actions 7 5 Operating mode Static Colour This setting is only relevant if the device is working in Stand Alone mode and is not controlled via DMX In this operating mode you have the...

Страница 35: ...asic colour in a range from 000 255 bright dark and confirm with Setup n Retro Flat Par 18x10W RGBWA UV item no 404358 Red green blue white amber UV n Retro Flat Par 18x12W RGBW item no 404364 Red gre...

Страница 36: ...immer curve determines how the brightness increases or decreases depending on the set DMX value Display Meaning Linear Linear proportional course S Curve Non linear curve with a distinctive flat profi...

Страница 37: ...djustable dimmer curves Depending on the selected DMX value 1 the device lights with a brightness 2 between 0 and 100 Confirm the selection with Setup Press Mode The selection is applied Operating Ret...

Страница 38: ...nd Down to select the menu item Dimmer Speed and confirm with Setup 3 With Up and Down you can choose between the following options n D Speed Fast Fast response n D Speed Smooth Slow response Confirm...

Страница 39: ...and confirm with Setup 3 With Up and Down you can set the time after which the display will be darkened auto matically Choose between 10 s 20 s 30 s 60 s or ON the display remains permanently on Conf...

Страница 40: ...h Setup 2 Use Up and Down to select the menu item Factory Reset and confirm with Setup 3 With Up and Down you can choose between Yes perform reset and No no reset Select Yes Confirm the selection with...

Страница 41: ...irm with Setup 3 With Up and Down you can choose how the device behaves in case of a disturbed DMX transmission Hold the current state is retained and Off device blackout Confirm the selection with Se...

Страница 42: ...DMX Synchronous and confirm with Setup 3 With Up and Down you can choose how connected devices behaves in case of a dis turbed DMX transmission ON devices are synchronised with each other and Off no...

Страница 43: ...own to select the menu item Temperature and confirm with Setup The display shows whether the unit s temperature is within the normal range dis play is Normal or whether it is too high display is Warni...

Страница 44: ...software version used by the device 3 Press Mode The menu is closed 7 8 Operating mode DMX This setting is only relevant if the device is controlled via a DMX controller 1 Press Mode use Up and Down t...

Страница 45: ...lat Par 18x10W RGBWA UV item no 404358 6 channel 8 channel or 10 channel n Retro Flat Par 18x12W RGBW item no 404364 4 channel 6 channel or 8 channel 4 Confirm with Setup 5 Press Mode The menu is clos...

Страница 46: ...7 9 Menu overview Retro Flat Par 18x10W RGBWA UV item no 404358 part 1 Operating LED PAR 46...

Страница 47: ...Retro Flat Par 18x10W RGBWA UV item no 404358 part 2 Operating Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 47...

Страница 48: ...Retro Flat Par 18x12W RGBW item no 404364 part 1 Operating LED PAR 48...

Страница 49: ...Retro Flat Par 18x12W RGBW item no 404364 part 2 Operating Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 49...

Страница 50: ...RGBWA UV item no 404358 Channel Value Function 1 0 255 Intensity red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 4 0 255 Intensity white 0 to 100 5 0 255 Intensity amber...

Страница 51: ...0 255 Dimmer 0 to 100 2 0 255 Intensity red 0 to 100 3 0 255 Intensity green 0 to 100 4 0 255 Intensity blue 0 to 100 5 0 255 Intensity white 0 to 100 6 0 255 Intensity amber 0 to 100 7 0 255 Intensi...

Страница 52: ...255 Dimmer 0 to 100 2 0 255 Intensity red 0 to 100 3 0 255 Intensity green 0 to 100 4 0 255 Intensity blue 0 to 100 5 0 255 Intensity white 0 to 100 6 0 255 Intensity amber 0 to 100 7 0 255 Intensity...

Страница 53: ...ramme 04 68 84 Programme 05 85 101 Programme 06 102 118 Programme 07 119 135 Programme 08 136 152 Programme 09 153 169 Programme 10 170 186 Programme 11 187 203 Programme 12 204 220 Programme 13 221 2...

Страница 54: ...A 0 I 0 30 44 R 0 G 255 B 0 W 0 A 0 I 0 45 59 R 0 G 0 B 255 W 0 A 0 I 0 60 74 R 0 G 0 B 0 W 255 A 0 I 0 75 89 R 0 G 0 B 0 W 0 A 255 I 0 90 104 R 0 G 0 B 0 W 0 A 0 I 255 105 119 R 255 G 180 B 0 W 0 A...

Страница 55: ...0 B 255 W 210 A 0 I 0 225 239 R 255 G 200 B 40 W 90 A 0 I 0 240 255 R 255 G 255 B 255 W 255 A 255 I 255 0 255 Progress speed if channel 8 17 237 from slow to fast 0 255 Sensitivity of the built in mi...

Страница 56: ...ed 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 4 0 255 Intensity white 0 to 100 7 14 Functions in 6 channel DMX mode Retro Flat Par 18x12W RGBW item no 404364 Channel Val...

Страница 57: ...to 100 7 15 Functions in 8 channel DMX mode Retro Flat Par 18x12W RGBW item no 404364 Channel Value Function 1 0 255 Dimmer 0 to 100 2 0 255 Intensity red 0 to 100 3 0 255 Intensity green 0 to 100 4 0...

Страница 58: ...e 01 colour selection with channel 7 17 33 Programme 02 34 50 Programme 03 51 67 Programme 04 68 84 Programme 05 85 101 Programme 06 102 118 Programme 07 119 135 Programme 08 136 152 Programme 09 153...

Страница 59: ...control 7 Colour selection If channel 6 1 16 0 15 R 0 G 0 B 0 W 0 16 31 R 255 G 0 B 0 W 0 32 47 R 0 G 255 B 0 W 0 48 63 R 0 G 0 B 255 W 0 64 79 R 0 G 0 B 0 W 255 80 95 R 255 G 150 B 0 W 0 96 111 R 25...

Страница 60: ...W 210 192 207 R 0 G 255 B 0 W 210 208 223 R 0 G 0 B 255 W 210 224 239 R 255 G 200 B 40 W 90 240 255 R 255 G 255 B 255 W 255 0 255 Progress speed if channel 6 17 237 from slow to fast 0 255 Sensitivit...

Страница 61: ...Power consumption 160 W Operating supply voltage AC 100 240 V 50 60 Hz Fuse 5 mm 20 mm 1 5 A 250 V slow blow Dimensions W H D 268 mm 266 mm 326 mm Weight 2 9 kg Retro Flat Par 18x10W RGBWA UV item no...

Страница 62: ...6 8 Power consumption 220 W Operating supply voltage AC 100 240 V 50 60 Hz Fuse 5 mm 20 mm 1 5 A 250 V slow blow Dimensions W H D 266 mm 268 mm 284 mm Weight 2 9 kg Retro Flat Par 18x12W RGBW item no...

Страница 63: ...result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX inpu...

Страница 64: ...ted DMX cables and do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may o...

Страница 65: ...ng another DMX controller 4 Check whether the DMX cables run near or parallel to high voltage cables that may cause damage or interfer ence to a DMX interface circuit The display shows the message Tem...

Страница 66: ...lation of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully The fan grids of the device must be cleaned on a re...

Страница 67: ...the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste Dispose of this...

Страница 68: ...Notes LED PAR 68...

Страница 69: ...Notes Retro Flat Par 18x10W RGBWA UV 18x12W RGBW 69...

Страница 70: ...Notes LED PAR 70...

Страница 71: ......

Страница 72: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: