background image

Just Right!

 

TMX-200225

 

 

 

2021 ThingsMatrix Inc. Confidential Information. All Rights Reserved.

 

 

ThingsMatrix Service Platform User Guide to get further details. If the user requires 

battery level alert, it can be enabled by configuring a policy on the Platform. Please 

refer to 

Data Management Service - Policy

 section in ThingsMatrix Service 

Platform User Guide. 

2.3.8 Optical Sensor 

 

The TMX09 has a built-in optical sensor. When the device is removed after 

installation and the sensor is exposed to light, it will be activated immediately and 
the TMX09 

will send a “DEVICE_REMOVED” alarm message to the Platform, together 

with the current location data. 

Information relevant to the “DEVICE_REMOVED” alarm is displayed on the Platform 

(including alert icon, alert record, etc.). Please refer to 

Assets Management Service 

- Device List

 section in ThingsMatrix Service Platform User Guide to get more 

details. 

2.3.9 Temperature Sensor 

The TMX09 has a built-in temperature sensor, which can measure the temperature 

around the device. The device uploads the location data and real-time temperature, 

which are displayed on the Platform. The device cannot trigger a temperature alert. 
Temperature alert (out of range) can only be triggered via the Platform settings. 

The device will report the temperature information without any additional 

configuration on the Platform by default. The temperature information is displayed 

on the Platform. Please refer to 

Assets Management Service - Device List

 section 

in ThingsMatrix Service Platform User Guide to get more details. If the user requires 

a temperature alert, this can be enabled by configuring a policy on the Platform. 

Please refer to 

Data Management Service - Policy

 section in ThingsMatrix Service 

Platform User Guide. 

Содержание TMX09

Страница 1: ...ThingsMatrix TMX 200225 2021 ThingsMatrix Inc Confidential Information All Rights Reserved TMX09 USER MANUAL...

Страница 2: ...2 3 2 Multiple Wake up Mechanisms 6 2 3 3 Position Monitor 7 2 3 4 AGPS 7 2 3 5 LBS 7 2 3 6 Blind Zone Compensation 7 2 3 7 Battery Level Detection 7 2 3 8 Optical Sensor 8 2 3 9 Temperature Sensor 8...

Страница 3: ...Mode 12 3 7 1 Introduction 12 3 7 2 Configuration Example 13 4 Device Data Fields 14 5 Troubleshooting 14 5 1 Inaccurate positioning of LBS 14 5 2 The device is offline 15 5 3 Unable to boot 15 5 4 N...

Страница 4: ...ical temperature and an accelerometer a magnetic sensor is also available as an option Additional details are as follows Easy installation without wires Built in large capacity disposable lithium ion...

Страница 5: ...mm IP Rating IP67 Embedded Sensors Optical Sensor Accelerometer Magnetic Sensor optional Temperature Sensor Data Transfer EDGE 296kbps DL 236 8kbps UL GPRS 107kbps DL 85 6kbps UL Location LBS Supporte...

Страница 6: ...from the Platform the device switches into Track Now Mode In this mode the device periodically reports the location information to the platform following the pre configured reporting interval until a...

Страница 7: ...the carrier network signal It is enabled when the TMX09 does not have GPS location information Please note that LBS is largely dependent on distance to surrounding network cell sites which could be up...

Страница 8: ...efer to Assets Management Service Device List section in ThingsMatrix Service Platform User Guide to get more details 2 3 9 Temperature Sensor The TMX09 has a built in temperature sensor which can mea...

Страница 9: ...will report the data according fixed report interval 3 3 Parameter Table Table 4 TMX09 Parameters Category Parameter Definition Remark Working Mode Mode Work Mode Users can select the required workin...

Страница 10: ...will wake up at 12 30 and report data Fixed Wakeup Time 3 Wakeup Time 3 Parameter format HH mm For example setup wakeup_time3 to be 16 00 the device will wake up at 16 00 and report data Fixed Wakeup...

Страница 11: ...ort interval to a month Storage Mode can be activated Storage Mode is off by default 3 5 2 Configuration Example If the device is required to report data every 10080 minutes Storage Mode can be config...

Страница 12: ...or motion After being woken up by vibration motion if no continuous vibration motion is detected for more than 4 seconds the device will go back to sleep The priority of Motion Static Mode is higher...

Страница 13: ...the interval between each alarm clock cannot be less than 5 minutes in order to improve position accuracy and connectivity with the server The device cannot be woken up by vibration motion in Clock Mo...

Страница 14: ...e V It shows the voltage of the battery ipAddress IP Address It shows the IP Address of the connection gpsSpeed GPS Speed It shows the speed reported by the GPS direction Direction It shows the direct...

Страница 15: ...use The SIM card does not have an active subscription The SIM card is inserted incorrectly The device is asleep Solution Replace the SIM card Correct the SIM card installation Expose optical sensor to...

Страница 16: ...se the device the user needs to open the top cover insert the SIM card correctly turn the power on and install the device in place The user can open the top cover by removing the 4 screws in the corne...

Страница 17: ...blinking GPRS connecting Slow blinking GPRS connected Solid On Module error 6 2 SIM Card Installation Open the SIM card holder cover insert the SIM card into the SIM card holder Ensure that the SIM ca...

Страница 18: ...lowly It may take up to 3 minutes 6 4 Device Installation Close the top cover after the device is powered up Peel one side of the supplied 3M double sided tape and place it on the bottom of the device...

Отзывы: