Just Right!
TMX-200225
2021 ThingsMatrix Inc. Confidential Information. All Rights Reserved.
Schedule Mode is off by default.
The time zone is UTC +00:00 (unit: minute) by default, which can be changed via
serial port, SMS, or on the Platform.
In Clock Mode, the wake-up time presets of the device can be modified. The user
can configure up to 4 wake-up time points (the interval between each alarm clock
cannot be less than 5 minutes), in order to improve position accuracy and
connectivity with the server. The device cannot be woken up by vibration/motion in
Clock Mode.
The user can select a working mode according to their specific use case (refer to
Table 3
).
3.7.2 Configuration Example
If the device is required to report data at 08:00, 12:30, 16:00 and 20:30 respectively,
the user can set the device to Clock Mode (for this example, the device is in the time
zone of UTC +08:00). The parameters can be configured as follows: