11.2.7 Command HP
<id>HP<parameter><CR>
Reference variable Sensor temperature control unit.
Access:
reading / writing
Description:
The pressure and acceleration sensors are thermally coupled
and can be heated. The "HP" command sets the setpoint for the
Sensor temperature controller.
The information is given in °C with one decimal place.
Parameter type:
unsigned integer
Parameter:
0...600: Reference variable 0...60.0°C
65535: Heating of pressure and acceleration sensors is
switched off
Note:
Disabled the heater of pressure and acceleration sensors
has no influence on the IEC conformity. Furthermore, ex-
ist the classification according to IEC.
Type return value:
unsigned integer
Return value:
see parameter
Value range:
0…600 / 65535
Initial value:
500
11.2.8 Command HT
<id>HT<parameter><CR>
Mode of the housing heater control.
Access:
reading / writing
Description:
The command sets the mode for the housing heater
(only possible at 4.3352.00.40x)
Note:
With this command, the galvanically separate housing
heater is activated at the contacts 7/8 or deactivated.
Parameter type:
unsigned integer
Parameter:
0: Heater off
1: Heater on (controlled to ~ 4°C)
Type return value:
unsigned integer
Return value:
see parameter
Value range:
0...1
Initial value:
1