7 Technical 

Data 

Characteristic

 

Description

 

Measuring range 

0.3...75 m/s 

Accuracy 

0.3...50 m/s 

1% of meas. value or < 0.2 m/s 

Survival speed 

80 m/s (min. 30 minutes) 

Permissible  
Ambient conditions 

- 50...+ 80°C, all occurring situations of relative humidity  
(incl. dew moistening) 

Output signal   

Form

   

rectangle, edge steepness < 1µsec 

Frequency

 

1082 Hz @ 50 m/s 

Amplitude

 

is supply voltage, max. 15 V 

Push-Pull

 

Output  

 output 

resistance: 

  typical 

100

 

 10V, 130

 @ 5V, 230

 @ 3.3V 

 

 

Constant power limiting on typical 25mA 

Open Drain 
Output

  

Drain resistance typical 50

, Pull-Up-voltage max. 30V 

 

            Constant power limiting on typical 50mA,  

Load  

 1 k

 

 

 

 200 nF (corresp. to length typical cable < 1km) 

Linearity 

Correlation factor r between frequency and wind speed 
y=0.0462* f +0.21  typical 
r > 0.999 99 

(4…20 m/s) 

Starting velocity 

< 0.3 m/s 

Resolution 

0.05 m wind run 

Distance constant 

< 3 m (acc. to ASTM D 5096 – 96)  3 m acc. to  ISO 17713-1 

Turbulent flow 

Deviation 

v turbulent compared with stationary horizontal flow 

-0.5% < 

v < +2% 

Frequency < 2 Hz 

Classification  
 

According to IEC 61400-12-1 (2005-12)  
Class A  classification index A 0.9 
Class B  classification index B 3.0  
Class S  classification index S 0.5  

Wind load 

Approx.. 100 N @ 75 m/s 

Heating 

Surface temperature of housing neck > 0°C 
at 20 m/s up to –10°C air temperature, at 10 m/s up to –20°C 
using the THIES icing standard 012002 on the housing neck. 
Heating regulated by temperature sensor 

Electrical supply for opto-
electronic scanning 

Voltage: 

3.3…48 V DC (galvanic isolation from housing) 

Current: 

130µA typ. 150µA max. @ 3,3V bis 15,0V (w/o external load) 

 

 

180µA typ. 200µA max. @ 15V bis 48V (w/o external load) 

Electrical supply for 
heating 

Voltage: 

24 V AC/DC, 54…65Hz (galvanic isolation from housing) 

Idling voltage:  max. 30 V AC, max. 48 V DC 
Capacity: 25 

 

Содержание 4.3351.00.000

Страница 1: ...4 3351 10 000 Instruction for Use 021519 01 09 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com...

Страница 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Страница 3: ...2 Electrical Mounting 6 5 2 1 Cable 6 5 2 1 1 Cable Recommendation 6 5 2 2 Cable Shield 6 5 2 2 1 Connecting Recommendation for the Cable Shield 7 5 2 3 Plug and Cable Mounting 8 5 3 Connecting Diagra...

Страница 4: ...oth running of the ball bearings and prevents the shaft and slot from icing up 3 Construction and Mode of Operation A low inertia cup star with 3 cups made of carbon fibre reinforced plastic is set in...

Страница 5: ...fulfilled the measuring instrument should be installed at a height at where the measurement values are not influenced by any local obstacles In any case the measuring instruments should be in stalled...

Страница 6: ...e inner diameter of the instrument carrier should be 20 mm based on plug and cable feed through 5 2 Electrical Mounting 5 2 1 Cable Solder a shielded cable with diameter 7 8 mm and a core cross sectio...

Страница 7: ...ng protection rod on the mast in isolated condition and ground lightning protection rod Alternatively Install separate lightning protection rod beside the measurement mast 3 Metallic measurement mast...

Страница 8: ...d back ward on the cable sheath 3 Soldering wire to the insert positioning shield in cable clamp 4 Screwing on cable clamp 5 Assembling remaining parts acc to upper plan 6 Tightening pull relief of ca...

Страница 9: ...red joint of the counter plug 1 2 3 4 5 6 7 8 Order No 4 3351 10 without heating Pin 7 u 8 are not connected Pin 5 u 6 Do not connect 9 16 021519 01 09 Pin Name Function 1 SIG Signal rectangle 2 GND G...

Страница 10: ...the cleaning of the device should use a damp cloth without chemical cleaning agents are used Certain symptoms of wear and tear can appear on the ball bearings after years of use These symptoms are exp...

Страница 11: ...m s Starting velocity 0 3 m s Resolution 0 05 m wind run Distance constant 3 m acc to ASTM D 5096 96 3 m acc to ISO 17713 1 Turbulent flow Deviation v turbulent compared with stationary horizontal fl...

Страница 12: ...ed cable in the shaft see connecting diagram Mounting Mounting on mast R 1 for ex DIN 2441 1 with separate adaptor option Dimensions See dimension diagram Weight approx 0 5 kg Protection IP 55 DIN 400...

Страница 13: ...to mast 1 m Mast clamp 40 80 mm Tube diameter 34 mm Material Aluminum Lightning rod For mounting the a m trav erse or hanger 4 3100 98 000 Dimension 12 mm 500 mm long 1050 mm high Material Aluminum A...

Страница 14: ...HE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equip ment designed for use within certain voltage limits 552 200...

Страница 15: ...15 16 021519 01 09...

Страница 16: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 16 16 02151...

Отзывы: