Installation
&
Users Guide
OIL HEATING SOLUTIONS
White Cased Oil Boiler
Страница 1: ...Installation Users Guide OIL HEATING SOLUTIONS White Cased Oil Boiler...
Страница 2: ...5 RESTART 6 INSTALLATION REGULATIONS 7 WATER CONNECTIONS 7 BOILER LOCATION 8 CONVENTIONAL FLUE INSTALLATION 9 BALANCED FLUE INSTALLATION 10 18 CONNECTING OIL SUPPLY 18 19 ELECTRICAL CONNECTION WIRING...
Страница 3: ...INVALID Warranty on the Heat Exchanger 5 Years Warranty on Burner and Controls 2 years CONDITIONS OF WARRANTY 1 Boiler MUST BE installed by an OFTEC registered engineer if not permission will be requi...
Страница 4: ...c firing of the burner will occur when the water temperature within the boiler falls below the control thermostat set point which will continue to run until the water temperature rises to the temperat...
Страница 5: ...on HIGH LIMIT STAT INDICATOR ORANGE The high limit lockout will illuminate when the water within the boiler is or has overheated e g reached a temperature above that set on the high limit thermostat...
Страница 6: ...d LOCKOUTS are a result of a fault in the operation of the boiler and can be attributed to following examples An interruption of the fuel supply Electrical Supply fault e g Extreme low voltage Failure...
Страница 7: ...nel will go out and the burner will commence the ignition start sequence After 15 seconds the Burner should fire normally PLEASE NOTE Should the Burner not start both lockout indicator on the Control...
Страница 8: ...Published or Recommended After installing the system it needs to be flushed with a cleanser like Fernox Heavy Duty Restore for fast acting removal of lime scale black sludge magnetite and other deposi...
Страница 9: ...ary pipework 600 F From an internal or external corner 600 G Above ground or balcony level 600 H From a surface or a boundary facing the terminal 600 J From a terminal facing the terminal 1200 K Verti...
Страница 10: ...chimney is recommended to minimize the occurrence of condensation 5 Cowls Cowls and pots that may restrict the flue should not be used 6 Draught Stabiliser Chimneys over 6 metres high may produce exce...
Страница 11: ...s installed in a confined space e g a cupboard This is to prevent over heating of components COMBUSTION AIR SUPPLY 25MM M IN WALL TERMINAL LENGTH COMBUSTION AIR SUPPLY BALANCED FLUE BOILERS 550mm kW 2...
Страница 12: ...ut Seal to flue connector and extension if required 4 Apply lubricant included in kit To the inner and outer seal taken care to only lubricant the lip of the seal MODEL Flue A B C D 50 70 3 125 176 76...
Страница 13: ...ough the wall a minimum of 176mm for 80mm flue and 185mm for 100mm flue FLUE EXTENSION The maximum horzontal flue level is 1450mm this can be achieved using the following extension kits 3 x kit 3 300m...
Страница 14: ...re mark CHECK then cut 2 Remove Conventional flue ring from top of boiler REMOVE CASING LID REMOVE FOIL REMOVE FLUE RING FIT SEALS AND LUBRICATE BOLT BOTTOM SECTION TO BOILER TEST POINT MODEL Flue A B...
Страница 15: ...pass through the wall Making sure that the terminal protudes through the wall a minimum of 176mm for 80mm flue and 185mm for 100mm flue 10 Connect vertical and horizontal section together 11 Secure ve...
Страница 16: ...70 The vertical flue is telescopic as supplied The flue has a range of 1020 2400mm from the top of the boiler to the flashing Extension kits of 300 and 950mm are available The maximum vertical length...
Страница 17: ...ith the clip 7 Refit boiler top panel insure the knock out in the panel has been removed 8 Assemble second vertical flue section and any vertical extension 9 Fit the roof flashing and flue terminal 10...
Страница 18: ...DAPTOR Disconnect Burner Plug Fit B F Adaptor Fit B F Adaptor Gasket Peel backing sticky from B F adaptor Gasket Remove C F Adaptor Tighten bolt on burner Fit snorkel tube Internal view Loosen Bolt Re...
Страница 19: ...IT4 80mm KIT4 100mm 5 VERTICAL FLUE KIT5 80mm KIT5 100mm 6 950 MM FLUE EXTENSION KIT6 80mm KIT6 100mm 7 45 DEGREE BENDS KIT8 80mm KIT8 100mm N B Kit 8 45 degree bends must only be used on kit 5 vertic...
Страница 20: ...E VALVE SENSOR TIGER LOOP MUST BE 1 UPRIGHT 2 OUTSIDE RESIDENCE Can be above or below burner VALVE FILL VENT OIL FULL LEVEL OIL LOWEST LEVEL OIL LEVEL FULL OIL LOWEST LEVEL FIRE VALVE OIL TANK Plastic...
Страница 21: ...ich connects with the boiler control panel The burner is supplied with a 4 wire cable plug which allows disconnection for maintenance 1 2 3 4 5 6 7 8 MAINS SOCKET CHASSIS EARTH MAINS LIMIT LOCKOUT BUR...
Страница 22: ...FICATIONS BOILER OUTPUT IN BTU 50 70 70 90 90 115 115 140 140 170 170 220 A mm 857 857 896 1025 1025 1025 B mm 590 590 630 671 671 721 C mm 420 420 450 490 490 539 D mm 140 140 140 140 140 140 E mm 93...
Страница 23: ...e oil supply system Set burner pump pressure Allow time for the boiler to reach normal operating temperature Check the smoke reading Measure the Co2 Measure net flue gas temperature Please Note Reduci...
Страница 24: ...BOILER WILL NOT START Check if mains electricity supply is reaching boiler control panel making sure control thermostat is turned on and time clock is calling for heat 23...
Страница 25: ...4 Ecoflam Minor 8 Ecoflam Minor 12 ITEM DESCRIPTION 1 Reset Button 2 Control Box 3 Ignition Transformer 4 Ignition Cables 5 Nozzle Assembly 6 Nozzle 7 Brake Plate 8 Blast Tube ST40 Blast Tube ST50 9 I...
Страница 26: ...0 H 80 H 80 H 80 H 80 H 80 H OIL PRESSURE BAR 7 5 8 0 9 5 9 0 9 5 10 8 0 8 5 9 0 7 5 9 5 11 0 9 0 9 0 10 0 10 0 9 5 8 0 FIRING RATE Kg hr 1 35 1 63 1 95 1 98 216 2 44 2 6 2 84 3 2 3 21 3 52 3 8 3 7 4...
Страница 27: ...l nor any part may be reproduced without permission Turkington Engineering Limited have a continuing research and development programme which occasionally necessitates changes to specifications herein...