background image

22

 

 

 

7. Appendix

 

 

 

7.1 Caution & Warning

 

 
 

1. 

The unit can only be repaired by qualified installer centre personnel or an authorised

 

dealer.

 

 

2. 

This appliance is not intended for use by persons (including children) with reduced 
physical sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. (for Europe market)

 

Children should be supervised to ensure that they do not play with the appliance.

 

 

3. 

Please make sure that the unit and power connection have good earthing, otherwise 
may cause electrical shock.

 

 

4. 

If the supply cord is damaged, it must be replaced by the manufacturer or our service

 

agent or similarly qualified person in order to avoid a hazard.

 

 

5. 

Directive 2002/96/EC (WEEE):

 

The symbol depicting a crossed-out waste bin that is underneath the appliance indi- 
cates that this product, at the end of its useful life, must be handled separately from 
domestic waste, must be taken to a recycling centre for electric and electronic devices 
or handed back to the dealer when purchasing an equivalent appliance.

 

 

6. 

Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC 
(RoHs) concerning restrictions for the use of harmful substances in electric and elec- 
tronic devices.

 

 

7. 

The unit CANNOT be installed near the flammable gas. Once there is any leakage of 
the gas, fire can be occur.

 

 

8. 

Make sure that there is a circuit breaker for the unit, lack of a circuit breaker can lead to

 

electrical shock or fire.

 

 

9. 

The heat pump is equipped with an over-load protection system. It does not allow for 
the unit to start for at least 3 minutes from a previous stoppage.

 

 

10. 

Installation must be performed in accordance with the NEC/CEC by authorized person

 

only. (for North America market)

 

 

11. 

USE SUPPLY WIRES SUITABLE FOR 75°C .

 

 

12. 

Caution: Single wall heat exchanger, not suitable for potable water connection.

 

 

Содержание 29kw

Страница 1: ...THERMOTEC INVERTER SWIMMING POOL HEAT PUMP Installation Instruction Manual for Vertical Models 29kw and 34kw Version 1 0...

Страница 2: ...e 9 3 5 Electrical Wiring 10 3 6 Initial Start up of the Unit 10 3 7 Condensation 11 4 Operation and Use 4 1 Display interface introduction 12 4 2 Button functions 13 4 3 Error codes 17 4 4 Error code...

Страница 3: ...aintenance and operation must be carried out according to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations...

Страница 4: ...1 Nominal power input kW 2 4 3 1 Max power input kW 28 6 33 7 Nominal Running current A 10 7 13 5 Current range A 2 5 to 30 3 1 to 30 6 Max Current A 30 30 6 Compressor quantity 1 1 Compressor type R...

Страница 5: ...5 2 2 Dimensions Thermotec Inverter Vertical 29kw and 34kw Thermotec Inverter 17 19 5 2 3 Removing the Case...

Страница 6: ...6 2 4 Connecting the Power Cable To connect the powe cable please remove the front panel of the heat pump and connect the power cable to the terminal block on the fron of the heat pump...

Страница 7: ...k air inlet These locations deny the unit of a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery 3 2 How Close To Your Pool Normally the pool heat pump...

Страница 8: ...s and noise 4 Always keep the heat pump in upright position If the unit has been tilted you should wait for at least 24 hours before turning it on 3 4 Installation of a check valve When using automati...

Страница 9: ...nger Start up Procedure After installation is completed you should follow these steps 1 Turn on your filter pump Check for water leaks and verify flow to and from the pool 2 Turn on the electrical pow...

Страница 10: ...itting on the side of the base pan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand and run to a suitable drain It is easy to mistake the condensation for a wa...

Страница 11: ...screen Locks the screen 3 Parameters Access to parameters 4 Clock settings Set the date time Activate timers 5 Error codes View error code history 6 Silent settings Press to activate silent function...

Страница 12: ...A 4 CLOCK SETTINGS In the main interface tap on the clock Settings button 3 interface displays as follows Setting the time tap on the Time Settings button 1 then the following menu pops up Tap the val...

Страница 13: ...e the START timer 2 Start time Set Start time 3 TIMER END Activated Red Not activated Grey Tap this button to activate deactivate the END timer 4 End time Set End time For example above without action...

Страница 14: ...ctivate the silent mode NO Name Button colour Button function 1 Timer SILENT OFF Activated Red Not activated Grey Tap to activate deactivate the END timer 2 Timer SILENT ON Activated Green Not activat...

Страница 15: ...g mode 3 Heating mode 4 Set desired swimming pool temperature 8 STATISTICS In the main screen tap the Statistics button A new menu will pop up The temperature curve automatically updates every hour an...

Страница 16: ...stem will record the time code and name of the error When an error occurs and you don t check the Error code history menu the main interface will display a static icon after a while If you do check Er...

Страница 17: ...ng protection E07 Water flow is not enough Check the pipe water flow and whether the water system is jammed or not The primary anti freezing protection E19 The ambient temp Is low The secondary anti f...

Страница 18: ...surement Voltage sampling fault F11 The input voltage sampling fault Check and adjust the current measurement DSP and PFC connect fault F12 DSP and PFC connect fault Check the communication connection...

Страница 19: ...19 Terminal Function V 12V power R Not used T Not used A 485A B 485B G GND power 5 Wiring diagrams 5 1 Wire control interface diagram and definition V R T A B G Thermotec Inverter 29kw...

Страница 20: ...20 Thermotec Inverter 34kw...

Страница 21: ...Should the unit begin to function abnormally or should you notice a smell from an electrical component arrange for timely repair or replacement Winterizing make sure to drain all the water from the he...

Страница 22: ...rneath the appliance indi cates that this product at the end of its useful life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices o...

Страница 23: ...Operating the product at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product 8 Chemical cont...

Страница 24: ...mary Lodge Church Road Ramsden Bellhouse Essex CM11 1RT United Kingdom Tel 44 1268 206560 www HeatPumps4Pools com enquiries heatpumps4pools com We reserve the right to change all or part of the conten...

Отзывы: