CONTROLLER
13
5.3.
Menu functions
By pressing the Button 3 (MENU/OK) the different menu windows can be cyclically navigated.
There are 5 main menu windows, in order to access the parameters of a menu, press the Button
3 (MENU/OK).
In order to modify a parameter, press the Button 3 (MENU/OK) with indication Set. At this
point, the indication will change to OK, and the chosen parameter will blink. Change the value
through the Buttons 2 (-) and 4 (+). Confirm the value by pressing the Button 3 (MENU/OK).
After setting the value, use the Buttons 2 (-) and 4 (+) to navigate to the next parameter.
Press the Button 1 (MODE/ESC) at any point to go up a menu level. Press the Button 5
(ON/OFF) at any point to exit to the main window.
5.3.1.
Water temperature
The water temperature for heating and sanitary mode can be set at this menu. On the display
the following message will appear:
MENU
PARAMETER
VALUE RANGE
RECOMMENDED
SETTING
Water temp.
Heating temp.
40-85
o
C
65-75
o
C
Sanitary temp.
30-65
o
C
45
o
C
5.3.2.
Date and time
The date and time can be set at this menu. On the display the following message will appear:
MENU
PARAMETER
VALUE RANGE
Date & Time
Time
00–23
Minutes
0–59
Day
Mo-Tu-We-Th-Fr-Sa-Su
Day Number
1–31
Month
1–12
Year
2010-2109
5.3.3.
Chronothermostat
In this menu, the user can set 6 different programs for each individual day of the week, this
meaning that there is a total available of 6*7=42 programs. On the display the following
message will appear:
e s c S e t
< W a t e r T e m p . >
e s c
S e t
< D a t e &
T i m e >